Material properties of arachnoid trabeculae in situ using inverse finite element analysis.
Leonardo Marin, Brittany Coats
Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA. · Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA. Electronic address: brittany.coats@utah.edu.
Key points
From the paper's conclusion- To address this unmet need, this study combined in situ, pressure-controlled subarachnoid inflation with optical coherence tomography imaging and inverse finite element (FE) analysis to calculate the material properties of individual arachnoid trabeculae.
Abstract
The pia-arachnoid complex (PAC), composed of pia mater, arachnoid mater, and arachnoid trabeculae, plays a critical role in transmitting mechanical forces between the brain and skull during head trauma. Despite its importance, the material properties of the PAC microstructure are unknown, limiting the accurate representation of the brain-skull interface in simulations of traumatic brain injuries. To address this unmet need, this study combined in situ, pressure-controlled subarachnoid inflation with optical coherence tomography imaging and inverse finite element (FE) analysis to calculate the material properties of individual arachnoid trabeculae. Individual FE models were created for 37 locations across piglets, pigs, and sheep brains. The elastic modulus was iteratively varied until the simulation matched the experimental arachnoid membrane displacement measured during inflation. The optimized models were validated by comparing individual trabeculae strains in the simulation to experimentally measured trabeculae strains, showing good agreement on average (7% difference). This indicates that material properties calculated from inverse FE analysis capture, on average, local single-trabecula behavior. The optimized inverse FE analysis yielded an average elastic modulus of 13.4 ± 13.6 kPa (median: 8.44kPa), with a linear elastic model adequately representing the experimental arachnoid membrane displacements (R2 = 0.96 ± 0.04). The elastic modulus of trabeculae across piglets, pigs, and sheep was not significantly different (p = 0.17). This work provides the first estimate of the microstructural-level mechanics of individual trabeculae in the PAC, opening the door to the development of microscale PAC models to support traumatic brain injury modeling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical behaviour of the intact brain-skull interface under tension, compression and sheararXiv · 2026
- The Biomechanical Mechanism of Cranial Implant Exposure Following Decreased Intracranial Pressure: A Finite Element Analysis Study.Biomedicines · 2026
- Biomechanically informed improvements to the brain-skull interface in an atlas-based brain model.Frontiers in bioengineering and biotechnology · 2026
- Rotational impact orientation effects traumatic brain injury severity, a biomimetic study.Journal of the mechanical behavior of biomedical materials · 2026
- Reassessment of two finite-element studies of infant head trauma: limits of the modelling evidence for shaking-induced bridging-vein rupture and protection by enlarged subarachnoid spaces.Frontiers in bioengineering and biotechnology · 2026
- Impact Testing System for an Anthropomorphic Craniocerebral Model with Enhanced Mechanical Fidelity.Brain research bulletin · 2026