Journal of ISAKOS : joint disorders & orthopaedic sports medicine

Local soft tissue thickness is not associated with radiographic component malpositioning in manual medial Oxford unicompartmental knee arthroplasty.

Moses Kd El Kayali, Samir Abu Salim, Luis V Buerck, Rosa Berndt, Lorenz Pichler, Clemens Gwinner, Danko Dan Milinkovic

Charité - Universitätsmedizin Berlin, Center for Musculoskeletal Surgery, Berlin, Germany; Institute for Clinical and Experimental Surgery, Saarland University, Homburg/Saar, Germany. Electronic address: moses.elkayali@charite.de. · Charité - Universitätsmedizin Berlin, Center for Musculoskeletal Surgery, Berlin, Germany.

Key points

From the paper's conclusion
  • LSTT measured at three anatomical regions showed no consistent associations with radiographic component positioning following manual medial Oxford UKA, except for weak associations with TPIT. No statistically significant differences in LSTT were observed between patients with component positioning within and outside the manufacturer's recommended radiographic ranges. Further studies with larger cohorts of patients are warranted to confirm these findings.

Abstract

INTRODUCTION/OBJECTIVES: Accurate component positioning is essential for successful unicompartmental knee arthroplasty (UKA). Although obesity has historically been considered a relative contraindication to UKA, whether obesity, as reflected by local soft tissue thickness (LSTT), compromises component positioning remains unclear. This study aimed to evaluate the association between regional LSTT and radiographic component positioning following manual medial UKA. METHODS: Consecutive patients undergoing primary manual medial UKA using a single implant system at one academic center between 2013 and 2023 were retrospectively screened. Standardized preoperative and postoperative radiographs were used to assess LSTT at three anatomical levels: ankle-adipose index, pretibial subcutaneous fat (PSF), and knee-adipose index (KAI). Radiographic component positioning was assessed using the femoral varus/valgus angle, femoral flexion/extension angle, tibial varus/valgus angle, and tibial posteroinferior tilt (TPIT). All measurements were performed independently by two blinded observers. Correlations between LSTT and component positioning parameters were assessed using Spearman's rank correlation coefficient. LSTT was compared between patients with all component positioning parameters within the manufacturer's recommended radiographic ranges and those with at least one parameter outside the recommended range using the Mann-Whitney U test. RESULTS: A total of 99 patients (41 females, 41.4%) met the inclusion criteria. Overall, 19 patients (19.2%) had at least one component positioning parameter outside the manufacturer's recommended range. Correlation analysis demonstrated weak positive correlations between TPIT and both PSF (ρ = 0.298, p = 0.003) and KAI (ρ = 0.302, p = 0.002). No statistically significant correlations were observed between the remaining component positioning parameters and any LSTT parameter. Furthermore, LSTT did not differ statistically significantly between patients with all components positioned within the manufacturer's recommended range and those with at least one component outside the recommended range (p > 0.05). CONCLUSION: LSTT measured at three anatomical regions showed no consistent associations with radiographic component positioning following manual medial Oxford UKA, except for weak associations with TPIT. No statistically significant differences in LSTT were observed between patients with component positioning within and outside the manufacturer's recommended radiographic ranges. Further studies with larger cohorts of patients are warranted to confirm these findings. LEVEL OF EVIDENCE: III, retrospective cohort study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers