Development and preliminary analytical evaluation of a magnetic particle-based chemiluminescent sandwich immunoassay for copeptin.
Guilin Li, Zhenzhen Guan, Songrui Li, Mengmeng Liu, Lingling Li, FeiYu Dong, Yige Guo, Weitao Zhang,
Zhengzhou Immunobiotech Co, Ltd, Zhengzhou 450001, PR China. · Zhengzhou Immunobiotech Co, Ltd, Zhengzhou 450001, PR China. Electronic address: zhaoqiaohui@autobio.com.cn.
Key points
From the paper's conclusion- The results for clinical samples correlated well with those obtained by LC-MS/MS (R2 = 0.95).
Abstract
This study aimed to independently develop domestic monoclonal antibodies against copeptin (CPP) and establish a magnetic particle-based chemiluminescence immunoassay to improve the accuracy and clinical applicability of early diagnosis of myocardial diseases. CPP amino-terminal and carboxyl-terminal peptides were synthesized by solid-phase peptide synthesis and conjugated to keyhole limpet hemocyanin (KLH) as immunogens. Mice were immunized subcutaneously, and mouse monoclonal antibodies against the amino-terminal region of CPP were generated using hybridoma technology; rabbits were immunized subcutaneously, and rabbit monoclonal antibodies against the carboxyl-terminal region of CPP were generated using phage display technology. The optimal antibody pair was selected by checkerboard titration, and a double-antibody sandwich assay system was established. Antibody affinity was characterized by bio-layer interferometry (BLI). The detection sensitivity of the assay and its consistency with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for clinical sample measurement were evaluated using the sandwich chemiluminescence method. A total of 25 mouse monoclonal antibodies and 4 rabbit monoclonal antibodies were obtained. Enzyme-linked immunosorbent assay identified the optimal pair as rabbit anti-CPP 1148# as the capture antibody and mouse anti-CPP 2# as the detection antibody, with equilibrium dissociation constants in the 10-10 M range. The limit of detection (LOD) of the assay was 0.03 ng/mL, and the coefficient of variation (CV) was below 5%. The results for clinical samples correlated well with those obtained by LC-MS/MS (R2 = 0.95). Bland-Altman analysis showed an estimated 95% limit of agreement ranging from -20.15 to -0.61 pg/mL, with consistency significantly superior to that of a commercially available kit. These monoclonal antibodies provide reliable core reagents for establishing a domestic CPP detection system and lay a foundation for the development of more reliable CPP diagnostic reagents.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of immunological reagents for the identification of biomarkers of inflammation in the common marmoset.bioRxiv : the preprint server for biology · 2026
- Serum-compatible screening and truncation optimization of copeptin aptamers for TdT-amplified fluorescent detection.Biosensors & bioelectronics · 2026
- A novel preparation method for monodisperse streptavidin magnetic beads and its application in electrochemiluminescent immunoassay for CEAPLoS ONE · 2025
- Direct Quantification of Complement Biomarkers Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).ACS pharmacology & translational science · 2026
- Development of CSF1R-Targeted Peptide Tracers for PET Imaging of LPS-Induced Pulmonary Inflammation.Analytical chemistry · 2026
- Serum-compatible aptamer-regulated RCA-CRISPR/Cas12a assay for fluorescence and lateral flow detection of myeloperoxidase.Mikrochimica acta · 2026