Phylogenetic Analysis and Plasma Resistance of Blood-Derived Escherichia coli Isolates that Cause Bacteremia at a Tertiary Care Hospital in Japan.
Hayato Nakamura, Naoko Imuta, Tadasuke Ooka, Hideki Kawamura, Yuki Obama, Masatoshi Nakamura, Tsuyoshi Kojo, Hiroki Yamakuchi,
Department of Microbiology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan. · Department of Infection Prevention and Control, Kagoshima University Hospital, Kagoshima, Japan.
Key points
From the paper's conclusion- ST131-C1 and ST1193 clones showed phenotypic characteristics associated with greater plasma resistance and/or may be associated with bloodstream survival. This study may offer a new perspective on the mechanisms underlying E. coli survival in the bloodstream.
Abstract
INTRODUCTION: Escherichia coli is a leading cause of human bacteremia, and multidrug-resistant clones such as ST131 and ST1193 have spread worldwide. However, few studies have investigated the genetic background including the evolutionary lineages of blood-derived E. coli isolates in patients with bacteremia in Japan. Furthermore, the factors contributing to its survival in the bloodstream are poorly understood. METHODS: From November 2019 to October 2021, we examined 132 consecutive blood-derived E. coli isolates from patients with bacteremia at Kagoshima University Hospital for multilocus sequence analysis and analysis of virulence factors, such as plasma resistance and biofilm formation. We then compared the microbiological and clinical characteristics between the main sequence type (ST) groups. RESULTS: The most prevalent ST group was ST131 (22.7%), which included ST131-C1 (12.9%) and ST131-C2 (6.8%), followed by ST73 (19.7%), ST95 (12.1%), and ST1193 (5.3%). The median plasma resistance index (PRI) was highest for ST131-C1 (0.590), followed by ST1193 (0.574), ST95 (0.466), ST131-C2 (0.432), and ST73 (0.335). The median biofilm index (BI) was highest for ST73 (0.229), followed by ST131-C2 (0.213), ST95 (0.185), ST131-C1 (0.131), and ST1193 (0.099). There was a weak inverse correlation between the PRI and BI (p=0.0159). The ST131-C1 and ST1193 strains accounted for a relatively high proportion of cases originating from non-urinary tract infections with poor prognosis. CONCLUSIONS: ST131-C1 and ST1193 clones showed phenotypic characteristics associated with greater plasma resistance and/or may be associated with bloodstream survival. This study may offer a new perspective on the mechanisms underlying E. coli survival in the bloodstream.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Genomic Insight into Escherichia coli Bloodstream Infections at a Tertiary Hospital in Shanghai: Predominance, Genetic Diversity, and Plasmid-Associated Virulence of CC131 and CC14.Antibiotics (Basel, Switzerland) · 2026
- From Phenotype to Genotype: A Clonal Perspective on Virulence and Biofilm Formation in Bloodstream-Derived Escherichia coli.Infection and drug resistance · 2026
- Clonal diversity and genetic characteristics of extraintestinal pathogenic Escherichia coli in northern Japan: identification of the potentially prevalent clones phylogroup B2-ST357 and ST1193.Journal of global antimicrobial resistance · 2026
- Phylogenetic Analysis, Association of Antibiotic Resistance and Biofilm-Production in Escherichia coli Clinical Isolates: A Single-Center Study.Microorganisms · 2026
- Genomic linkage and plasmid variation among ST393 extended-spectrum β-lactamase-producing Escherichia coli isolates from a mother–preterm-infant pairFrontiers in Microbiology · 2026
- Mapping the evolutionary path towards multi-drug resistance in the pandemic Escherichia coli ST131 lineage.Microbial genomics · 2026