The Cylinder Test: Development and clinical validation of a tool for assessing hand opening.
Therese Ramström, Lina Bunketorp Käll, Johanna Wangdell
Institute of Clinical Sciences, Department of Hand Surgery at Sahlgrenska Academy, University of Gothenburg, Göteborgsvägen 31, Mölndal 431 80, Sweden; Department of Occupational Therapy and Physiotherapy, Sahlgrenska University Hospital, Mölndal Hospital, Mölndal, Sweden, Länsmansgatan 28, Mölndal 431 30, Sweden; Centre for Advanced Reconstruction of Extremities, Sahlgrenska University Hospital/Mölndal, Länsmansgatan 28, Mölndal, 431 30, Sweden. Electronic address: therese.ramstrom@gu.se. · Institute of Clinical Sciences, Department of Hand Surgery at Sahlgrenska Academy, University of Gothenburg, Göteborgsvägen 31, Mölndal 431 80, Sweden; Centre for Advanced Reconstruction of Extremities, Sahlgrenska University Hospital/Mölndal, Länsmansgatan 28, Mölndal, 431 30, Sweden; Institute of Neuroscience and Physiology, Department of Health and Rehabilitation, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Key points
From the paper's conclusion- Preliminary evaluation supports the face validity, manual clarity, feasibility, and perceived clinical relevance of the CyT for assessing functional hand opening in neurological upper limb rehabilitation. The CyT may provide hand therapists with a clinically feasible approach to assessing active and passive hand opening. Further evaluation of reliability, construct validity, and responsiveness is required.
Abstract
BACKGROUND: Impaired hand opening following neurological injury can limit functional grasp and object handling. Existing upper limb assessments do not specifically evaluate functional hand opening or distinguish between active and passive components. PURPOSE: To describe the development of the Cylinder Test (CyT) and evaluate its preliminary face validity, manual clarity, feasibility, and perceived clinical relevance among clinicians and individuals with neurological upper limb impairment. STUDY DESIGN: Clinical measurement, cross-sectional study. METHODS: The CyT was developed through iterative clinical refinement and literature review. The final CyT version comprises 14 plastic cylinders (20-150 mm diameter) and four subtests assessing active and passive functional hand opening. Face validity was evaluated in 33 individuals with neurological upper limb impairments due to cervical spinal cord injuries (cSCI) or spasticity and 31 clinicians experienced in neurological upper limb rehabilitation. Clinicians reviewed the CyT manual and completed a study-specific questionnaire assessing clarity, perceived clinical usefulness, relevance of the subtests, and scoring criteria. Participants performed the CyT and subsequently rated its relevance and perceived effort. Data were summarized descriptively. RESULTS: All clinicians (31/31, 100%) reported that the manual provided sufficient guidance for independent administration, and all considered the CyT potentially useful in clinical practice. The purpose of the CyT was rated as clear or very clear by 26/31 clinicians (84%), and no clinician rated any subtest or scoring criterion as inappropriate. All participants (33/33, 100%) rated the overall CyT as relevant or very relevant, and ratings of the individual subtests were predominantly relevant or very relevant. Six of 15 participants with spasticity rated the test as demanding compared with 2/18 participants with cSCI. CONCLUSIONS: Preliminary evaluation supports the face validity, manual clarity, feasibility, and perceived clinical relevance of the CyT for assessing functional hand opening in neurological upper limb rehabilitation. The CyT may provide hand therapists with a clinically feasible approach to assessing active and passive hand opening. Further evaluation of reliability, construct validity, and responsiveness is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-Camera AI-Based Classification of Clinically Defined Grasp Patterns in Children with Cerebral Palsy.Sensors (Basel, Switzerland) · 2026
- A user-friendly graphical user interface for paw touch classification in rodent cylinder testing.Frontiers in neuroscience · 2026
- Defining Constructs of Hand Function Quality at Home After Cervical Spinal Cord Injury Through Egocentric Videos: A Qualitative InquirymedRxiv · 2026
- Competency Assessment for Ultrasound-Guided Pharmacopuncture in Pain Management: Development and Initial Validity Evidence for an OSCE Checklist.Pain research & management · 2026
- Classification of patient-defined hand-arm treatment goals in young people with cerebral palsy and upper extremity spasticity undergoing upper extremity surgeryDisability and Rehabilitation · 2026
- Pressure garment therapy and bimanual upper limb function in children with unilateral cerebral palsy: A randomized clinical trial.Developmental medicine and child neurology · 2026