Optimal Positioning of Specialized Ulnar Shortening Plates to Reduce Hardware Irritation After Ulnar Shortening Osteotomy.
Yeongyoon Koh, Kanghun Yu, In Cheul Choi, Jong Woong Park
Department of Orthopedic Surgery, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Republic of Korea. · Department of Orthopedic Surgery, College of Medicine, Korea University Anam Hospital, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Plate surface location does not independently predict hardware irritation after USO with specialized plates. The distance from the ulnar styloid tip to the distal plate edge was the only significant independent predictor, and positioning the distal plate edge at least approximately 30 mm from the ulnar styloid tip-regardless of plate surface-may serve as a practical clinical reference to reduce the risk of hardware irritation and the need for secondary plate removal.
Abstract
PURPOSE: Hardware irritation is a common complication following ulnar shortening osteotomy (USO) and often requires secondary plate removal. Although plate surface location and distal plate positioning have been proposed as contributing factors, their independent effects remain poorly defined. This study evaluated the influence of plate location and distal plate position on hardware irritation in patients treated with specialized USO plates. METHODS: We retrospectively reviewed 145 patients who underwent USO with specialized ulnar shortening plates between 2016 and 2025. Plate location was classified as dorsal, ulnar, or palmar. The distance from the ulnar styloid tip to the distal edge of the plate was measured on postoperative radiographs. Multivariable logistic regression was used to identify independent predictors of hardware irritation, and receiver operating characteristic (ROC) curve analysis was performed in each subgroup to determine an optimal distance cutoff. RESULTS: Hardware irritation occurred in 37 patients (26%). Plate location (dorsal, ulnar, or palmar) was not independently associated with irritation (P = .238). On multivariable logistic regression, a shorter distance from the ulnar styloid tip to the distal plate edge was the only significant independent predictor of hardware irritation (odds ratio [OR], 0.63; 95% confidence interval [CI], 0.54-0.75; P < .001). ROC curve analysis identified location-specific optimal cutoffs: 31 mm for dorsal (area under the curve [AUC], 0.882), 33 mm for ulnar (AUC, 0.927), and 31 mm for palmar placement (AUC, 0.977). In each subgroup, plates positioned below the respective cutoff had a significantly higher irritation rate (dorsal: 53% vs 8%, P = .001; ulnar: 55% vs 3%, P < .001; palmar: 85% vs 9%, P < .001). To facilitate clinical application, a uniform 30-mm threshold applied across all locations also demonstrated strong discriminatory performance (overall AUC, 0.918; 67% vs 9% irritation rate; P < .001). CONCLUSIONS: Plate surface location does not independently predict hardware irritation after USO with specialized plates. The distance from the ulnar styloid tip to the distal plate edge was the only significant independent predictor, and positioning the distal plate edge at least approximately 30 mm from the ulnar styloid tip-regardless of plate surface-may serve as a practical clinical reference to reduce the risk of hardware irritation and the need for secondary plate removal. TYPE OF STUDY/LEVEL OF EVIDENCE: Retrospective cohort study, IV.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simplified Ulnar Shortening Osteotomy Using Interosseous Wire Fixation: A Reproducible Freehand Approach.The journal of hand surgery Asian-Pacific volume · 2026
- Coronal Alignment and Ulnar Deviation After Radial-Sided Lateral-Approach Silicone Arthroplasty of the Proximal and Distal Interphalangeal Joints: A Prospective Case Series.Hand (New York, N.Y.) · 2026
- Comparison of Hockey-Stick and Conventional Linear Ultrasound Transducers for Detection of Non-Displaced Dentoalveolar Fractures: An Ex Vivo Paired Comparative Study.Tomography (Ann Arbor, Mich.) · 2026
- Anatomic Considerations of Retrograde Intramedullary Nail Placement in Distal Ulna Fractures.The Journal of hand surgery · 2026
- Growth-Adjusted Comparison of Angular Change After Radioulnar Fracture Repair with and Without Concurrent Ulnar Ostectomy in Immature Small-Breed Dogs.Veterinary sciences · 2026
- Long-term implant retention after impacted elastic stable intramedullary nailing in pediatric diaphyseal forearm fractures: a retrospective cohort studyActa Orthopaedica · 2026