Electrocatalytic ozonation for removal of pharmaceuticals, pathogenic microorganisms, and antibiotic resistance genes from hospital wastewater.
Lingyun Gu, Chunxiu Yu, Yi Wu, Xingxing An, Kexin Chen, Jialiang Huang, Xuejie Wang, Zhaokun Xiong,
Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China; State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Chengdu 610041, China. · Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China; State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Chengdu 610041, China.
Key points
From the paper's conclusion- Collectively, these results demonstrate that the ECO system holds significant potential for the simultaneous removal of pharmaceuticals, pathogens, and ARGs from hospital wastewater.
Abstract
The widespread use of antibiotics, particularly in hospital wastewater, accelerates the proliferation of antibiotic-resistant genes (ARGs), posing a global threat. To address this challenge, an efficient electrocatalytic ozonation (ECO) process was constructed by injecting diffused ozone bubbles, using stainless steel and graphite as the anode and cathode. The ECO system exhibited superior catalytic performance in degrading dexamethasone (DXMS) with pseudo-first-order reaction rate constants (kobs, 0.401 min-1), which is 4 and 93 times higher than those of ozonation and electrolysis alone, respectively. Hydroxyl radicals(•OH) were identified as the primary reactive species. The ECO process effectively reduced bacterial culturability of Escherichia coli (E. coli) in 5 min by disrupting cell integrity and DNA structure. In real hospital wastewater treatment, the ECO system maintained a COD removal efficiency of 72.25% - 86.82% and eliminated 81 of the 119 detected pharmaceutical contaminants, achieving an average removal rate of 85.42%. The removal efficiencies for various ARGs ranged from -7.73-99.13%. The ECO process effectively caused substantial DNA degradation and altered the relative abundance of ARGs and microbial taxa in hospital wastewater. Collectively, these results demonstrate that the ECO system holds significant potential for the simultaneous removal of pharmaceuticals, pathogens, and ARGs from hospital wastewater.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Emerging contaminants in hospital wastewater: A critical review of characteristics, fate, risks, and treatment.Journal of hazardous materials · 2026
- Risk assessment of the spread of antibiotic resistance genes from hospitals to the receiving environment via wastewater treatment plantsEcotoxicology and Environmental Safety · 2025
- Silver‐Loaded Carbon‐Doped Carbon Nitride for Efficient Elimination of Drug‐Resistant Providencia Alcalifaciens and QnrS2 Antibiotic Resistance GenesAdvanced Sustainable Systems · 2026
- Pilot-scale simultaneous coupling ozonation and biodegradation for enhancing pollutant removal and mitigating antibiotic resistance genes in penicillin intermediate wastewater.Bioresource technology · 2026
- Expanded granular sludge blanket coupled aerobic membrane bioreactor treating swine wastewater: Simultaneous removal of organics-ciprofloxacin and distribution of antibiotic resistance genes.Bioresource technology · 2026
- Electrocatalytic membrane-assisted chlorination overcomes the paradoxical increase in antibiotic resistance gene transformation risk.Environmental science and pollution research international · 2026