Journal of hazardous materials

Tracing contamination sources and geochemical processes in groundwater of industrial complex using multiple isotopes (Zn, Cr, S-O of sulfate, and H-O of water), PCA, and PMF.

Dae-Gyu Im, Duk-Min Kim, Jung-Woo Hwang, Seong-Taek Yun

Department of Earth and Environmental Sciences, Korea University, Seoul 02841, South Korea. · Department of Civil and Environmental Engineering, Sangji University, Wonju 26339, South Korea. Electronic address: kdukmin8@sangji.ac.kr.

Key points

From the paper's conclusion
  • Among the 10 samples analyzed for sulfate isotopes, DS-11 showed increased δ³⁴S-SO₄ indicating bacterial sulfate reduction, with stable Δ¹⁸O(SO₄-H₂O) values suggesting oxygen exchange. δ⁶⁶Zn (n = 26; -0.32-1.04‰) was inversely related to dissolved Zn (R² = 0.60, p < 0.001), suggesting in-aquifer Zn sulfide (ZnS) precipitation. δ⁵³Cr (n = 3; 1.14-1.84‰) exceeded the industrial electroplating range

Abstract

A multi-tracer framework combining rank-based principal component analysis (PCA), positive matrix factorization (PMF), and four stable-isotope systems was applied to 26 groundwater samples from three industrial zones and a residential reference area in South Korea. Trace metals were elevated in the industrial zones, with Cr reaching 17,324 and Zn 2026 µg L⁻¹ . PMF resolved four sources: sewage (Factor 1, NO₃⁻-dominant) at residential and Zone 2 wells, industrial SO₄²⁻ (Factor 2) at Zone 3 wells, reduction of Mn-Fe (oxy)hydroxides (Factor 3), and Zn alloy/plating (Factor 4). Three roadside wells showed low deuterium excess (d-excess, down to -1.7‰), suggesting characteristics of sewage. Among the 10 samples analyzed for sulfate isotopes, DS-11 showed increased δ³⁴S-SO₄ indicating bacterial sulfate reduction, with stable Δ¹⁸O(SO₄-H₂O) values suggesting oxygen exchange. δ⁶⁶Zn (n = 26; -0.32-1.04‰) was inversely related to dissolved Zn (R² = 0.60, p < 0.001), suggesting in-aquifer Zn sulfide (ZnS) precipitation. δ⁵³Cr (n = 3; 1.14-1.84‰) exceeded the industrial electroplating range (≈0‰), suggesting Cr(VI) reduction at those wells. The framework thus separated contaminant sources from in-aquifer attenuation. This separation, unattainable from dissolved concentrations alone, supports targeted remediation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Tracing contamination sources and geochemical processes in groundwater of industrial complex using multiple isotopes (Zn, Cr, S-O of sulfate, and H-O of water), PCA, and PMF — Science Skim