Response to the commentary on "trace cisplatin adsorption by thiol-functionalized sponge (TFS) and Sn/SnO₂-coated TFS: Adsorption study and mechanism investigation".
Dong Han, Manuel Valiente, Montserrat López-Mesas
GTS-UAB Research Group, Department of Chemistry, Faculty of Science, Universitat Universitat Autònoma de Barcelona, Bellaterra, (Cerdanyola del Vallès), Barcelona 08193, Spain; National Food Institute (DTU Food), Technical University of Denmark, Kgs., Lyngby, Denmark. Electronic address: donha@food.dtu.dk. · GTS-UAB Research Group, Department of Chemistry, Faculty of Science, Universitat Universitat Autònoma de Barcelona, Bellaterra, (Cerdanyola del Vallès), Barcelona 08193, Spain.
Key points
From the paper's conclusion- This response addresses the Commentary by Lima et al. on our study "Trace cisplatin adsorption by thiol-functionalized sponge (TFS) and Sn/SnO₂-coated TFS: Adsorption study and mechanism investigation".
Abstract
This response addresses the Commentary by Lima et al. on our study "Trace cisplatin adsorption by thiol-functionalized sponge (TFS) and Sn/SnO₂-coated TFS: Adsorption study and mechanism investigation". The discussion focuses on three main issues: the interpretation of the Dubinin-Radushkevich mean adsorption energy, the treatment of equilibrium constants in adsorption thermodynamics, and the use of three temperature points in the van't Hoff analysis. We clarify that the D-R parameter E was not used as a standalone proof of chemisorption, but as supporting evidence interpreted together with adsorption behavior, surface chemistry, and spectroscopic observations. We further discuss why conversion of adsorption constants into thermodynamic equilibrium constants must depend on the assumptions of the underlying adsorption model, particularly for systems that are not well described by the Langmuir model. Finally, we acknowledge the statistical limitations of a three-temperature van't Hoff analysis, while arguing that limited statistical power should not be equated with mathematical invalidity. Overall, we emphasize that adsorption thermodynamic parameters should be interpreted within the physical and model-specific context of the investigated system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Commentary on "Trace cisplatin adsorption by thiol-functionalized sponge (TFS) and Sn/SnO₂-coated TFS: Adsorption study and mechanism investigation".Journal of hazardous materials · 2026
- Comment on “SolubilityBehavior of MeglumineForm I in 12 Pure Solvents: Experimental Measurements, ThermodynamicModeling, And Solvation Mechanism Analysis”Journal of Chemical & Engineering Data · 2026
- An International Laboratory Comparison Study on Approximating the Enthalpy of Adsorption via the Clausius‐Clapeyron ApproachChemPhysChem · 2026
- Toward consistent thermodynamic modeling of CO2 adsorption on Lewatit VPOC 1065 under dry conditions: isotherm variability, data gaps, and model fittingCurrent Opinion in Chemical Engineering · 2025
- Asymptotic connections between Elovich, PFO and PSO adsorption kinetics in a coverage-dependent rate modelScientific Electronic Archives · 2026
- Entropy-derived Lewis acid-base thermodynamic parameters of solid surfaces: A generalized five-parameter framework for polar adsorption entropy and molecular organization by inverse gas chromatography.Journal of chromatography. A · 2026