Temporal morphological differentiation of menstrual and peripheral bloodstains on a semi-porous substrate: A controlled stereo-microscopic study.
Mayur Sudhir Balbudhe, B Suresh Kumar Shetty, Adithi Shetty, Nayanatara Arun Kumar, Shankar M Bakkannavar
Department of Forensic Medicine and Toxicology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India. Electronic address: mayur.kmcmlr2024@learner.manipal.edu. · Department of Forensic Medicine and Toxicology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India. Electronic address: suresh.shetty@manipal.edu.
Key points
From the paper's conclusion- This non-destructive optical method is simple and complements high-end techniques such as hyperspectral imaging, Raman spectroscopy, and immunochromatographic assays (e.g., the SERATEC PMB test). It may be helpful in preliminary bloodstain pattern analysis (BPA). The use of a single substrate and controlled conditions limits these findings; nonetheless, the standardised methodology and findings provide a reproducible basis for future multi-substrate and field-applicable investigations in the forensic differentiation of blood origins.
Abstract
BACKGROUND: It is not a new problem that menstrual blood and peripheral blood are difficult to distinguish in a forensic context, especially when analysing an alleged sexual assault, domestic violence, or unexplained injury. In this context, the place of bloodstains may provide significant contextual detail. METHODS: This controlled study examined temporal morphological variations in menstrual and peripheral bloodstains, with an emphasis on stain diameter, deposited on glossy paper (a semi-porous surface) under controlled environmental conditions (22 ± 1°C, 50 ± 5% relative humidity). Stain diameters were measured at six time points after deposition: 10 min, 1 h, 2 h, 24 h, 72 h, and 120 h, in triplicate, under stereo microscopy (2× magnification) with ABFO-scale calibration. Group differences were evaluated using repeated-measures ANOVA (p < 0.05), followed by post hoc Tukey tests. RESULTS: The diameter of peripheral bloodstains contracted statistically significantly over time, stabilising with minimal variability. In contrast, the diameter of menstrual bloodstains contracted initially and then stabilised, showing relative dimensional stability with systematically higher variability. The differences are explained by the biochemical composition of menstrual blood (high mucus content, endometrial debris, fibrinolytic activity, lower haematocrit), differing from that of peripheral blood (fibrinogen-mediated clotting, higher plasma protein concentration). CONCLUSION: This non-destructive optical method is simple and complements high-end techniques such as hyperspectral imaging, Raman spectroscopy, and immunochromatographic assays (e.g., the SERATEC PMB test). It may be helpful in preliminary bloodstain pattern analysis (BPA). The use of a single substrate and controlled conditions limits these findings; nonetheless, the standardised methodology and findings provide a reproducible basis for future multi-substrate and field-applicable investigations in the forensic differentiation of blood origins.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a procedure for the simultaneous detection of mRNA markers in menstrual blood, vaginal fluid, and peripheral blood for the purpose of discriminating between menstruation and traumatic vaginal injury in sexual assault cases.Legal medicine (Tokyo, Japan) · 2026
- Temperature-dependent stability of the miR-451a/miR-21-5p expression ratio for forensic discrimination of menstrual from peripheral blood.Legal medicine (Tokyo, Japan) · 2026
- Blood footwear impression depletion: comparative morphological and biochemical analysis of continuous and interrupted partial-drying transfer sequences.International journal of legal medicine · 2026
- Twelve-month tracking of metabolomic changes in ex vivo bloodstains: the analytical validity window of bloodstain metabolites.Forensic science, medicine, and pathology · 2026
- Calprotectin-targeted latex agglutination assay for the rapid and sensitive detection of vaginal fluid and menstrual blood.Journal of forensic sciences · 2026
- Harnessing Machine Learning to Evaluate Microscopic Characteristics of Skeletal Trauma.Forensic science international · 2026