High-fidelity dose calculation for atmospheric dispersion modelling: Revisiting the Suffield Full-Scale RDD Field Trials.
Jens Peter K W Frankemölle, Luke S Lebel
KU Leuven, Dept. Mechanical Engineering, Celestijnenlaan 300, Leuven, BE-3000, Belgium; SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol, BE-2400, Belgium. Electronic address: jenspeter.frankemoelle@kuleuven.be. · Canadian Nuclear Laboratories, 286 Plant Rd, Chalk River, ON K0J 1J0, Canada.
Key points
From the paper's conclusion- We benchmark our model on results from the Suffield Full-Scale Radiological Dispersal Device (FSRDD) Field Trials, which involved the detonation of three explosives labelled with lanthanum-140, and monitoring of their dispersion in the near range.
Abstract
Atmospheric dispersion models (ADM) are important radiation protection tools for modelling the public consequences of a radiological release. Conventional ADM approaches, like Gaussian plume models, have known limitations, and so much active research goes into improved flow modelling. However, in the radiological and nuclear field it is also important to be able to calculate the external doses. Conventional external dose models often break apart as well in the near range, because of heterogeneity of the plumes and deposition fields. In this work, we present an improved external dose modelling technique for use in ADM based on three-dimensional (3D) finite cloud modelling. For this, we adapted the Atmospheric Dispersion and Dose Equivalent Rates (ADDER) model by (I) including a puff algorithm alongside the existing plume algorithm, (II) implementing the Briggs' rural dispersion parameterisation and (III) implementing a bespoke RDD puff rise algorithm that builds on previous work by Sharon et al. (2012). We benchmark our model on results from the Suffield Full-Scale Radiological Dispersal Device (FSRDD) Field Trials, which involved the detonation of three explosives labelled with lanthanum-140, and monitoring of their dispersion in the near range. We report the correspondence between deposition, ground shine and cloud shine model predictions and measurements. For the ground shine measurements, we quantitatively compare a direct dose conversion model with our finite ground algorithm. For 2/3 trials, we report FAC2>0.5, NAD<0.5, MG≤1.33 and VG≤2.0 for the ground shine computed with our finite algorithm. While previous studies of the FSRDD Field Trials only looked at time-integrated metrics, here, we also report continuous-in-time model predictions and measurements. We see future potential in coupling our external dose model to a more detailed Computational Fluid Dynamics (CFD) dispersion model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Urban radiological risk assessment using HotSpot and Geant4: From probabilistic dose estimates to shielding effects.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A spatiotemporally corrected radiological contamination mapping platform for multi-scenario nuclear and radiological emergencies.Journal of environmental radioactivity · 2026
- A rapid atmospheric radionuclide dispersion prediction and dose assessment method based on the physics-aware spatio-temporal neural operator.Journal of environmental radioactivity · 2026
- Urban Dose Rate Estimation Using Distributed Static D3S Gamma-Ray Spectrometers.Sensors (Basel, Switzerland) · 2026
- Study on tissue dose field of delayed gamma emitted from fission products under effects of blast waveNuclear Techniques · 2026
- Simulation of spread and dispersion of Kr and Xe noble gas radionuclides in a hypothetical accident in the Tehran Research Reactor.Radiation and environmental biophysics · 2026