KU Leuven, Dept. Mechanical Engineering, Celestijnenlaan 300, Leuven, BE-3000, Belgium; SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol, BE-2400, Belgium. Electronic address: jenspeter.frankemoelle@kuleuven.be. · Canadian Nuclear Laboratories, 286 Plant Rd, Chalk River, ON K0J 1J0, Canada.

Computational

Key points

From the paper's conclusion
  • We benchmark our model on results from the Suffield Full-Scale Radiological Dispersal Device (FSRDD) Field Trials, which involved the detonation of three explosives labelled with lanthanum-140, and monitoring of their dispersion in the near range.

Abstract

Atmospheric dispersion models (ADM) are important radiation protection tools for modelling the public consequences of a radiological release. Conventional ADM approaches, like Gaussian plume models, have known limitations, and so much active research goes into improved flow modelling. However, in the radiological and nuclear field it is also important to be able to calculate the external doses. Conventional external dose models often break apart as well in the near range, because of heterogeneity of the plumes and deposition fields. In this work, we present an improved external dose modelling technique for use in ADM based on three-dimensional (3D) finite cloud modelling. For this, we adapted the Atmospheric Dispersion and Dose Equivalent Rates (ADDER) model by (I) including a puff algorithm alongside the existing plume algorithm, (II) implementing the Briggs' rural dispersion parameterisation and (III) implementing a bespoke RDD puff rise algorithm that builds on previous work by Sharon et al. (2012). We benchmark our model on results from the Suffield Full-Scale Radiological Dispersal Device (FSRDD) Field Trials, which involved the detonation of three explosives labelled with lanthanum-140, and monitoring of their dispersion in the near range. We report the correspondence between deposition, ground shine and cloud shine model predictions and measurements. For the ground shine measurements, we quantitatively compare a direct dose conversion model with our finite ground algorithm. For 2/3 trials, we report FAC2>0.5, NAD<0.5, MG≤1.33 and VG≤2.0 for the ground shine computed with our finite algorithm. While previous studies of the FSRDD Field Trials only looked at time-integrated metrics, here, we also report continuous-in-time model predictions and measurements. We see future potential in coupling our external dose model to a more detailed Computational Fluid Dynamics (CFD) dispersion model.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers