Partitioning and retention of PFAS in a Salix-planted constructed wetland treating foam-fractionated leachate and groundwater.
Oscar Liljeström, Dahn Rosenquist, Dan B Kleja, Anja Enell, Lutz Ahrens
Swedish University of Agricultural Sciences (SLU), Department of Aquatic Sciences and Assessment, P. O. Box 7050, SE-750 07, Uppsala, Sweden. Electronic address: oscar.liljestrom@slu.se. · Laqua Treatment AB, Siriusvägen 16, SE-296 92, Yngsjö, Sweden.
Key points
From the paper's conclusion- Overall, this CW configuration reduced PFAS mass load rather than aqueous concentrations, suggesting limited suitability as a polishing step.
Abstract
Per- and polyfluoroalkyl substances (PFAS) are persistent and mobile contaminants frequently detected in landfill leachate and leachate-impacted groundwater, posing risks to environmental and human health. In this study, a pilot-scale (147 m2) subsurface flow constructed wetland (CW), planted with Salix sp. in a peat-biochar substrate, was evaluated as a post-foam fractionation treatment step. Over 176 days, 72.9 m3 of PFAS-contaminated water was treated. The CW reduced the water volume by 48% via evapotranspiration (2.11 L m-2 d-1), but PFAS concentrations did not decrease significantly between influent and effluent. In contrast, a mass balance indicated that 51% (50.7 mg) of the influent PFAS mass was retained within the system. The PFAS retention was primarily associated with the evapotranspiration-driven volume reduction and sorption to the filter substrate, particularly for long-chain PFAS. Short-chain PFAS were retained to a lower extent by the substrate but preferentially accumulated in Salix biomass. Plant uptake accounted for 6.9% of total retained PFAS, with 82-84% of accumulated PFAS located in leaves. No evidence of retranslocation during senescence was observed, indicating potential remobilization via leaf litter unless biomass is managed. The estimated phytoextraction potential of the system for PFAS ranged from 77 to 230 mg ha-1 yr-1, dominated by short-chain compounds. Overall, this CW configuration reduced PFAS mass load rather than aqueous concentrations, suggesting limited suitability as a polishing step. The CW technology could instead be useful as a pre-treatment step prior to advanced treatment, in order to reduce both water volume and contaminant load.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pilot scale treatment of PFAS-contaminated groundwater in a subsurface flow constructed wetland-evaluating multiple plant species.Environmental pollution (Barking, Essex : 1987) · 2025
- Influence of root morphology and salinity on PFAS uptake by ten Australian wetland plant species.Journal of hazardous materials · 2026
- Function of Submerged Macrophytes in the Distribution of Per- and Polyfluoroalkyl Substances (PFAS) Alternatives in Constructed Wetlands: Role of Extracellular Polymeric Substances (EPS) in the PhyllosphereEnvironmental Science & Technology · 2026
- Multiscale risk assessment of PFASs in concentrated stormwater infiltration systems: Coupling molecular mechanisms, microbial succession, and long-term hydrological simulations.Journal of hazardous materials · 2026
- Identification of a PFAS hyperaccumulator and elucidation of its translocation mechanism for sustainable phytoremediationNature Communications · 2025
- Techno-Economic Assessment of Treatment Methods to Remediate PFAS Contamination in Leachate of Closed Landfills in Rural MinnesotaChemEngineering · 2026