Automatically measured fragmented QRS has limited reproducibility between recordings and adds little to routine electrocardiographic variables: a pre-specified analysis of 92,698 electrocardiograms.
José Nunes de Alencar, Antonio Amorim Araújo Filho
Instituto Dante Pazzanese de Cardiologia, Av. Dr. Dante Pazzanese 500, Vila Mariana, São Paulo, SP 04012-909, Brazil. Electronic address: jose.alencar@dantepazzanese.org.br. · Maternidade Escola Januário Cicco, Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN, Brazil.
Key points
From the paper's conclusion- Automatically measured fQRS had limited reproducibility between recordings and added little clinically meaningful information beyond routine clinical and electrocardiographic variables. Visual reading was also inconsistent. These findings do not address visually identified fQRS in specific diseases.
Abstract
BACKGROUND: Fragmented QRS (fQRS), defined by notching of the QRS complex, is widely used as a marker of myocardial scar. Whether it is reproducible across serial recordings is unknown. METHODS: We automatically measured fragmentation features, the Das criteria, and QRS micro-fragmentation in 92,698 MIMIC-IV electrocardiograms (ECGs) and assessed agreement in 29,781 same-patient pairs recorded within 6 h, and incremental value for echocardiographic akinesis or dyskinesis, ejection fraction ≤40%, prevalent and incident infarction, incident ventricular arrhythmia, and 1-year mortality. Two electrocardiologists each read 330 tracings (150 random pairs plus 30 duplicates), blinded to pairing and to each other. RESULTS: Automated notch measures failed the pre-specified κ ≥0.60 threshold: 0.41 for a notch in a given lead, 0.43 for 2 or more notched leads, 0.52 for the Das criteria. Terminal S-wave slurring met the threshold, and the most stable composite tracked the QRS axis. Notch measures did not improve discrimination in the expected direction. The Das criteria improved mortality discrimination through an inverse association (odds ratio, 0.54; 95% CI, 0.51-0.58) that attenuated after full adjustment, including heart rate and QRS voltage (0.81; 0.76-0.87). QRS micro-fragmentation added little, varying across partitions. Inter-rater κ for fQRS in any lead was 0.40 (95% CI, 0.28-0.51), each reader's own between-recordings κ was 0.37 and 0.30, and neither agreed with the algorithmic Das criteria. CONCLUSIONS: Automatically measured fQRS had limited reproducibility between recordings and added little clinically meaningful information beyond routine clinical and electrocardiographic variables. Visual reading was also inconsistent. These findings do not address visually identified fQRS in specific diseases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fragmented QRS and mortality risk in patients with acute coronary occlusion myocardial infarction.Journal of cardiovascular medicine (Hagerstown, Md.) · 2026
- QRS micro-fragmentation as a mortality predictor in the emergency department: a dual-center retrospective cohort studyEuropean Heart Journal · 2026
- Associations of ECG-derived markers with clinical and biological characteristics in systemic sclerosis: preliminary findings from the SCAR-SSc study.Journal of medicine and life · 2026
- Association of fragmented QRS complex with mortality and clinical outcomes in patients with pulmonary embolism: an updated meta-analysis.BMJ open · 2026
- Diagnostic Performance of Automated versus Human ECG Interpretation for Prior Myocardial Infarction Using CMR as the Reference StandardEuropean Heart Journal - Digital Health · 2026
- Recurrence analysis of cardiac arrhythmias: A systematic review of methods, substrate characterisation and clinical translation.Computers in biology and medicine · 2026