Agreement of 12‑lead-derived atrial vectorcardiography with simultaneously recorded Frank leads in normal hearts and after myocardial infarction.
Alireza Sepehri Shamloo, Roman Michalski, Carmen Kolokowsky, Daniel Sedding, Arash Arya
Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Campus Charité Mitte, Augustenburger Platz 1, 13353 Berlin, Germany. · Department of Internal Medicine III, University Hospital Halle (Saale), Martin-Luther University Halle-Wittenberg, Ernst-Grube-Straße 40, 06120 Halle (Saale), Germany.
Key points
From the paper's conclusion- Agreement of derived atrial vectorcardiography depends on axis and outcome, so the transformation should be chosen for the specific measure studied. Between-cohort differences were associated with lead-axis concordance but cannot be attributed to infarction. Gain correction requires external validation; diagnostic or prognostic value was not assessed.
Abstract
BACKGROUND: Spatial P-wave analysis usually relies on vectorcardiograms derived from the 12‑lead ECG with transformations developed for ventricular signals or validated mainly in normal hearts. OBJECTIVE: To quantify agreement of inverse Dower, Kors and Guillem P-wave least-squares (PLSV) reconstructions with simultaneously recorded Frank P waves in normal participants and after myocardial infarction. METHODS: From the PTB Diagnostic ECG Database, 44 participants classified as normal and 85 patients with predominantly recent myocardial infarction (median 10.5 days) in sinus rhythm met prespecified quality criteria. Agreement within annotated P-wave windows was assessed by Pearson and concordance correlation, root-mean-square error, angular error and Bland-Altman analysis; cohort differences were examined with adjusted and sensitivity analyses. RESULTS: No transformation was uniformly superior. In the infarction cohort PLSV had the highest leftward-axis waveform correlation (0.975, versus 0.959 for Kors and 0.924 for inverse Dower). This correlation was lower than in normal participants for inverse Dower (-0.028) and Kors (-0.019) but not significantly for PLSV (-0.003; 95% CI -0.012 to 0.006). The difference attenuated after accounting for lower Frank Vx-lead V6 concordance in the infarction cohort (42% versus 11% below r = 0.90). PLSV underestimated P-vector magnitude by 14% in both cohorts; within this database, normal-derived gain correction almost eliminated this bias and nearly halved median absolute error. CONCLUSION: Agreement of derived atrial vectorcardiography depends on axis and outcome, so the transformation should be chosen for the specific measure studied. Between-cohort differences were associated with lead-axis concordance but cannot be attributed to infarction. Gain correction requires external validation; diagnostic or prognostic value was not assessed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reconstructive information content of ECG leads and electrodes in premature ventricular contractions: an exhaustive, dual-population study.Journal of electrocardiology · 2026
- Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.Journal of electrocardiology · 2026
- Reconstructing the range-normalized terminal QRS from V1 and V6 using the time-embedded 3D ECGmedRxiv · 2026
- Inverted Lead III (-III) at -60° as a Complementary Frontal Lead in Anterior STEMI: A Vector-Based Approach to Anterolateral and Basal Extension.Current problems in cardiology · 2026
- Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.Journal of electrocardiology · 2026
- Electrocardiographic Imaging via Posterior Sampling under Operator DiscrepancyarXiv · 2026