From the paper's conclusion
  • During controlled LAD balloon occlusion, RWPT in the V2-V1 PBL increased more than during RCA or LCx occlusion, with exploratory discriminatory value. Reproducibility, incremental value over the standard ECG, and clinical applicability remain to be established.

Abstract

BACKGROUND: Early recognition of acute left anterior descending (LAD) coronary occlusion is important. Beyond ST-segment elevation, ischemia also alters ventricular depolarization. We examined whether R-wave peak time (RWPT) in the V2-V1 precordial bipolar lead (PBL) changes during controlled coronary balloon occlusion and whether the change differs between LAD and non-LAD occlusion. METHODS: Secondary analysis of the STAFF III database. In 45 patients undergoing elective balloon angioplasty without prior infarction, RWPT in the V2-V1 PBL was measured at baseline and during occlusion of the LAD (n = 16), RCA (n = 17) or LCx (n = 12), one pair per patient. The primary analysis was the within-patient change and its between-territory contrast (LAD vs RCA + LCx); exploratory ROC analyses assessed discrimination. Thresholds are exploratory. RESULTS: RWPT increased during LAD occlusion (median 43.5 → 54.5 ms; Wilcoxon p = 0.0022; positive in 12/16); changes were not significant for RCA (42.0 → 41.0 ms; p = 0.195) or LCx (37.5 → 36.0 ms; p = 0.720). Median ΔRWPT was +7.5 ms (LAD) vs 0 (RCA) and - 1.0 ms (LCx); the LAD vs non-LAD difference was significant (Mann-Whitney p < 0.001). ΔRWPT discriminated LAD with an AUC of 0.84 (95% CI 0.72-0.94) and absolute occlusion RWPT 0.78 (0.60-0.93). ΔRWPT ≥10 ms gave 43.8% sensitivity and 89.7% specificity; RWPT ≥50 ms gave 62.5% and 89.7%. Specificity is against other occluded arteries, not non-occlusion. CONCLUSIONS: During controlled LAD balloon occlusion, RWPT in the V2-V1 PBL increased more than during RCA or LCx occlusion, with exploratory discriminatory value. Reproducibility, incremental value over the standard ECG, and clinical applicability remain to be established.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers