Effects of 850-nm light-emitting diode photobiomodulation on pain intensity and dentin sialoprotein levels during canine distalization: A randomized controlled trial.
Thanh Thuy-Nhat Cao, Anh Ho-Quynh Nguyen, Hung Trong Hoang, Tham Dong Khac, Phuc Hoai Le, H K Tu Trinh, Kieu-Minh Le, Diem Truong
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam. · Center for Molecular Biomedicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Key points
From the paper's conclusion- Repeated 850-nm LED PBM was associated with reduced cumulative pain and attenuated DSP increases during canine distalization, suggesting potential benefits for patient comfort and root resorption-related responses.
Abstract
BACKGROUND/PURPOSE: Light-emitting diode-based photobiomodulation (LED PBM) potentially reduces pain and root resorption risk in orthodontics. This study evaluated 850-nm LED PBM effects on pain and dentin sialoprotein (DSP) levels during canine distalization. MATERIALS AND METHODS: This single-blind, parallel-group randomized controlled trial included 16 orthodontic patients (8 per group). Participants were randomly allocated in a 1:1 ratio to either an active LED group or a sham control group. Pain intensity was assessed using a visual analog scale (VAS) at 0, 24, and 48 h following canine distalization at four consecutive monthly visits (T1-T4) and expressed as the area under the curve (AUC0-48h). DSP concentrations in gingival crevicular fluid were measured at pretreatment (T0), initiation of distalization (T1), and follow-up visits (T2, T3) using sandwich ELISA. Longitudinal changes were analyzed using linear mixed-effects models. RESULTS: The LED group demonstrated a significantly lower pain intensity compared with the control group, with a significant group-by-time interaction (χ2=9.46, P=0.024). Adjusted mean values of AUC0-48h were significantly reduced in the LED group at T3 and T4, with the greatest difference observed at T3 (P < 0.001). A significant group-by-time interaction was observed for DSP (χ2 = 9.75, P = 0.021), with lower DSP levels in the LED group being reported at T1, T2, and T3 compared with the control group (P < 0.05). CONCLUSION: Repeated 850-nm LED PBM was associated with reduced cumulative pain and attenuated DSP increases during canine distalization, suggesting potential benefits for patient comfort and root resorption-related responses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of 810-nm Diode Laser Photobiomodulation on Pain and Patient-Reported Satisfaction after Initial Fixed Orthodontic Appliance Placement: A Randomized Sham-Controlled Single-Blind Clinical Trial.Photobiomodulation, photomedicine, and laser surgery · 2026
- Effect of photobiomodulation on recovery from oral soft tissue local anaesthesia in paediatric patients: a preliminary split-mouth randomized clinical trial.Lasers in medical science · 2026
- Photobiomodulation Reduces Physiological Stress and Pain During Dental Diagnostic Procedures: The UM-DANE 1 Pediatric Clinical Trial.Pediatric dentistry · 2026
- Comparative Evaluation of Photobiomodulation and Intracanal Cryotherapy on Post-Endodontic Pain Following Single-Visit Root Canal Treatment: A Randomized Controlled Trial.Cureus · 2026
- Effects of 660 nm & 808 nm photo-biomodulation on S100A8/A9 in symptomatic pulpitis: a randomized controlled trial.Lasers in medical science · 2026
- Biphasic energy dependent effects of 650 nm diode laser photobiomodulation on orthodontic tooth movement and compression zone bone remodeling in vivoBMC Oral Health · 2026