Journal of dentistry

Accuracy and Efficiency of Artificial Intelligence-assisted Dental Restoration Design: A systematic Review and Meta-analysis.

Nadin Al-Haj Husain, Hüseyin Seker, Hyuing-In Yoon, Richard Johannes Wierichs, Burak Yilmaz

Unit for Practice-based Research, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. · Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, School of Dental Medicine, Bern, Switzerland; Department of Prosthodontics, Faculty of Dentistry, Aydın Adnan Menderes University, Aydın, Turkey.

Meta-analysis

Key points

From the paper's conclusion
  • Evidence, almost entirely in vitro studies and highly heterogeneous, is inconclusive regarding differences in design time, morphological accuracy and restoration fit. Design time tended to be shorter with AI-assisted software.

Abstract

OBJECTIVES: To compare the accuracy and time efficiency of artificial intelligence (AI)-assisted software with conventional dental computer-aided design (CAD) software for designing dental restorations. DATA AND SOURCES: Following PRISMA 2020, five electronic databases (PubMed, Web of Science, Embase, Scopus, and the Cochrane Library) were searched to August 4, 2026. In vitro and clinical studies comparing AI-assisted and conventional CAD software for digital dental restoration design were eligible. Outcomes included design time, morphology, restoration fit, and proximal and occlusal contacts. Risk of bias was assessed using the QUIN tool. Random-effects meta-analyses (REML, Hartung-Knapp adjustment) were performed, with 95% prediction intervals (PI), τ and I² with 95% CIs. STUDY SELECTION/RESULTS: Twenty-eight studies met the eligibility criteria; 10 were pooled. Design time (4 studies) showed a non-significant mean difference of -258.4 s (95% CI -543.2 to 26.4; 95% PI -1100.2 to 583.5). Pooled SMDs were -2.05 for root mean square deviation (8 studies; 95% CI -4.88 to 0.78; 95% PI -10.25 to 6.15). Heterogeneity was substantial (I² = 80-97%, τ=0.82-3.13). Restoration fit (marginal gap, marginal fit, internal fit; three studies or fewer each) and occlusal outcomes were synthesized narratively. AI-assisted software generally produced clinically acceptable restorations, although technician refinement remained beneficial. AI-assisted software generally produced clinically acceptable restorations, although technician refinement remained beneficial for contour, emergence profile, and occlusal contacts. CONCLUSIONS: Evidence, almost entirely in vitro studies and highly heterogeneous, is inconclusive regarding differences in design time, morphological accuracy and restoration fit. Design time tended to be shorter with AI-assisted software. CLINICAL SIGNIFICANCE: AI-assisted design software may shorten design time, but current evidence does not allow firm conclusions about restoration quality relative to conventional CAD. Well-designed, preferably clinical, comparative studies with standardized outcomes are needed for further evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers