Journal of dentistry

Digitally Guided Root Membrane Preparation Using a Dedicated Apex Guide for Immediate Implant Placement: A Retrospective Case Series.

Sam Omar, Francesco Guido Mangano

OneDay Clinic, Lab and Academy, Shalz Mall, 2nd floor, El Sheikh Zayed city 7th district, Mogawra 2, Giza Governorate, 12593 Egypt. Electronic address: dr.samomar@gmail.com. · Department of Orthodontics and Dental Disease Prevention, Sechenov First Moscow State Medical University, 121059 Moscow, Russian Federation. Electronic address: francescoguidomangano@gmail.com.

Case report

Key points

From the paper's conclusion
  • The Apex Guide workflow was clinically feasible in this small series. RM-related complications occurred despite complete implant survival; comparative accuracy and long-term safety remain unestablished.

Abstract

OBJECTIVE: To assess the clinical feasibility and 1-year outcomes of a static computer-assisted workflow using a dedicated Apex Guide for root membrane (RM) preparation and immediate implant placement. METHODS: Fifteen consecutive patients with nine anterior and six posterior single-tooth sites were included. Cone-beam computed tomography and intraoral scans were registered for planning. A tooth-supported Apex Guide guided a 2.0-mm drill along a root-oriented trajectory; implant placement used a separate prosthetically driven guide. Feasibility, complications, survival, Pink Esthetic Score (PES), probing depth (PD), bleeding on probing (BOP), recession and peri-implant marginal bone level (PIMBL) were assessed. RESULTS: Guided access and RM preparation were completed in all sites without intraoperative RM or facial bone damage. One RM became mobile and required removal; another developed internal exposure requiring reduction. RM retention was 93.3% (14/15), and implant and prosthetic survival were 100%. Between 6 months and 1 year, PES (12.13 ± 0.74 vs 12.20 ± 0.77; P = 0.317), PD (2.22 ± 0.15 vs 2.21 ± 0.10 mm; P = 0.655), BOP (3.34 ± 6.91% vs 2.23 ± 5.88%; P = 0.317) and PIMBL (0.280 ± 0.039 vs 0.281 ± 0.035 mm; P = 0.387) showed no significant changes. One screw loosening reduced prosthetic success to 93.3%. CONCLUSIONS: The Apex Guide workflow was clinically feasible in this small series. RM-related complications occurred despite complete implant survival; comparative accuracy and long-term safety remain unestablished. CLINICAL RELEVANCE: Static guidance may assist apical access during RM preparation while allowing independent, prosthetically driven implant placement.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers