Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology

Andes virus molecular diagnosis and viral RNA kinetics using a research use only RT-PCR assay: Experience from a Spanish tertiary hospital.

Guillermo Arán Toha, Ana Collazos Blanco, Ana Belén Negredo, Alicia Inés García Señán, Ana Sarria Visa, Sara Medrano Pardo, Miriam Estébanez, German Ramíez-Olivencia,

Department of clinical Microbiology and Parasitology, Hospital Central de la Defensa "Gómez-Ulla" C.S.V.E., Madrid, Spain. · Centro Nacional de Microbiología, Instituto de Salud Carlos III, CNM-ISCIII, Madrid, Spain.

Key points

From the paper's conclusion
  • The RealStar® Hantavirus-HPS RT-PCR assay showed high qualitative agreement with the reference method in the clinical specimens evaluated and provided timely molecular information during outbreak investigation and longitudinal follow-up. Whole blood may be useful for longitudinal detection of ANDV RNA; however, these findings are descriptive and do not establish generalized viral shedding kinetics or infectivity. Further analytical and clinical studies are required to establish the assay's performance and clinical utility.

Abstract

OBJECTIVES: To evaluate the clinical performance and qualitative agreement of a commercially available Research Use Only (RUO) real-time RT-PCR assay for Andes virus (ANDV) detection and longitudinal molecular monitoring during the first imported ANDV outbreak managed in Spain. METHODS: Fourteen repatriated individuals exposed to an ANDV outbreak underwent molecular screening using whole blood and serum specimens. Confirmed cases were prospectively monitored with serial whole blood, serum, oropharyngeal swab, urine, and rectal swab specimens collected every 72 h. Clinical specimens were inactivated in a Biosafety Level 3 facility before automated RNA extraction and testing with the RealStar® Hantavirus-HPS RT-PCR assay (Altona Diagnostics, Hamburg, Germany). All specimens were also analyzed at the Spanish National Reference Laboratory using a hantavirus-specific real-time RT-PCR reference method. Qualitative agreement, Ct value correlation, and viral RNA kinetics were assessed. RESULTS: A total of 185 clinical specimens were analyzed, including 124 screening specimens from exposed individuals and 61 specimens collected during longitudinal follow-up of two confirmed cases. All 124 screening specimens were negative by both assays (124/124, 100% agreement). Among follow-up specimens, overall qualitative agreement was 93.4% (57/61; κ=0.837), and Ct values showed a strong correlation between assays (Pearson's r = 0.965). Four discordant results occurred in specimens with high Ct values (≥34-35), consistent with low concentrations of detectable viral RNA. Whole blood showed the lowest Ct values and the longest persistence of detectable viral RNA among the specimen types evaluated. CONCLUSIONS: The RealStar® Hantavirus-HPS RT-PCR assay showed high qualitative agreement with the reference method in the clinical specimens evaluated and provided timely molecular information during outbreak investigation and longitudinal follow-up. Whole blood may be useful for longitudinal detection of ANDV RNA; however, these findings are descriptive and do not establish generalized viral shedding kinetics or infectivity. Further analytical and clinical studies are required to establish the assay's performance and clinical utility.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Andes virus molecular diagnosis and viral RNA kinetics using a research use only RT-PCR assay: Experience from a Spanish tertiary hospital — Science Skim