Evaluation of measurement properties of PROMs used in UK NIHR-funded musculoskeletal RCTs: A COSMIN-style systematic review.
Kim Borsky, Jing Qin Tay, Anahita Mahmoudzadeh, Eden Leaper, Peter Springall, Felix Fischer, David Beard, Jeremy Rodrigues,
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK; Surgical Intervention Trials Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK. Electronic address: kim.borsky@ndorms.ox.ac.uk. · Oxford University Hospitals, Oxford, UK.
Key points
From the paper's conclusion- This review highlights limitations and uncertainties in the validation literature supporting PROMs selected as primary outcomes in recent NIHR-funded MSK RCTs. None of the nine PROMs met the stringent COSMIN criteria for recommendation, although this does not necessarily imply that they are unsuitable for use in clinical trials. Structural validity was a consistent limitation, whereas reliability and internal consistency were relatively strong. These findings highlight the uncertainty faced by funders, trialists and policymakers, and emphasise the need for more rigorous, hypothesis-driven validation studies alongside pragmatic, transparent PROM selection.
Abstract
INTRODUCTION: Patient-Reported Outcome Measures (PROMs) are widely employed in randomised controlled trials (RCTs) in musculoskeletal (MSK) research to capture outcomes that matter most to patients. However, many PROMs lack detailed evaluations of their measurement properties, possibly affecting the validity and interpretability of PROM-derived outcomes. The COSMIN initiative provides standards for evaluating a PROM's measurement properties. This systematic review aimed to appraise the measurement properties of PROMs recently used as primary outcomes in UK NIHR-funded MSK RCTs according to COSMIN standards. STUDY DESIGN AND SETTING: We identified RCTs funded by three major NIHR programmes between January 2023 and December 2024 that specified a PROM as their primary outcome. Eligible trials were restricted to adult MSK populations, excluding pilot or feasibility trials. Nine different PROMs were identified: SPADI, RAPID3, KOOS, OSS, MOXFQ, MSK HQ, OHIP-TMD, PRUNE, and OARS. A systematic search of PubMed, EMBASE, and PsycINFO (inception-March 2025) was conducted using COSMIN search filters. Validation studies were screened in duplicate, with data extraction guided by COSMIN methodology. Each measurement property was rated as sufficient, insufficient, or indeterminate, and the quality of evidence graded using the GRADE approach. COSMIN recommendations were formulated for each PROM. RESULTS: From 26,598 records, 91 articles (180 studies) were included. Validation evidence varied widely across PROMs, with a median of 19 studies per instrument (range 3-48). Only three PROMs (SPADI, KOOS, MSK HQ) had evidence assessing all measurement properties recommended by COSMIN. None met the COSMIN threshold for an unreserved recommendation for use. SPADI, OSS, MOXFQ, and MSK HQ received recommendations against use in their current form based on high-quality evidence of insufficient structural validity. The remaining PROMs received "no conclusion" recommendations, largely reflecting inconsistent findings, low evidence quality, or unassessed measurement properties. Across all instruments, structural validity was consistently insufficient or indeterminate, whereas reliability was consistently sufficient. Reliability and internal consistency showed the strongest quality ratings, although the latter was limited by unresolved unidimensionality concerns. Construct validity and responsiveness demonstrated mixed or inconsistent results, frequently downgraded due to poor methodological rigour. Measurement invariance testing revealed differential item functioning by age, gender, or disease subgroup in SPADI, KOOS, and MSK HQ. Only RAPID3 was assessed for criterion validity, receiving a sufficient rating but with low-quality evidence. CONCLUSION: This review highlights limitations and uncertainties in the validation literature supporting PROMs selected as primary outcomes in recent NIHR-funded MSK RCTs. None of the nine PROMs met the stringent COSMIN criteria for recommendation, although this does not necessarily imply that they are unsuitable for use in clinical trials. Structural validity was a consistent limitation, whereas reliability and internal consistency were relatively strong. These findings highlight the uncertainty faced by funders, trialists and policymakers, and emphasise the need for more rigorous, hypothesis-driven validation studies alongside pragmatic, transparent PROM selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Measurement properties of patient-reported outcome measures used in third molar surgery: a COSMIN-based systematic review.International journal of oral and maxillofacial surgery · 2026
- Measuring What Matters in Radiology: A Guide to Selecting, Implementing, and Interpreting Patient-Reported Outcome MeasuresCanadian Association of Radiologists Journal · 2025
- The right measure for the right question: A framework for domain-matched patient-reported outcome measure selection in knee arthroplasty research.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
- Outcome Assessment in Frozen Shoulder Trials: A Systematic Review and COSMIN-Informed Recommendations.Complementary therapies in medicine · 2026
- A systematic review of psychometric properties of physical fitness and physical functioning outcome measures applied in adult people with hemophilia.Archives of physiotherapy · 2026
- Systematic review of fatigue assessment instruments for systemic lupus erythematosus: psychometric validation with COSMIN 2.0 Guidelines.Rheumatology (Oxford, England) · 2026