Journal of colloid and interface science

Polydopamine-assisted immobilization of amide-bridged graphene oxide/ε-polylysine composite coating on titanium implant: Fabrication and multimodal antibacterial mechanism.

Jinglin Zhang, Zengsheng Li, Lizhen Chen, Langhuan Huang, Suiping Deng, Jingxian Zhang, Yongqiang Xiong, Shaozao Tan

Guangdong Engineering & Technology Research Centre of Graphene-like Materials and Products, Department of Chemistry, College of Chemistry and Materials Science, Jinan University, Guangzhou 510632, PR China; School of Textiles, Guangdong Polytechnic, Foshan 528041, PR China. · Guangdong Engineering & Technology Research Centre of Graphene-like Materials and Products, Department of Chemistry, College of Chemistry and Materials Science, Jinan University, Guangzhou 510632, PR China.

Key points

From the paper's conclusion
  • 100% bactericidal efficiency against E. coli and 99.54% against S. aureus, while in vivo tissue infection model showed a 97.21% antibacterial rate for the coating against S. aureus.

Abstract

In clinical practice, due to the lack of antibacterial capacity of titanium (Ti) metal, implant-associated infection remains an important factor leading to implant failure. To tackle this thorny challenge, we fabricated a composite via amidation reaction between graphene oxide (GO) and ε-polylysine (ε-PL) antimicrobial peptide, denoted as GO@ε-PL. By utilizing the good interfacial adhesion of polydopamine, GO@ε-PL was stably immobilized onto the surface of Ti substrate, and a Ti-based composite coating (i.e., Ti/GO@ε-PL) was successfully prepared. Herein, the scientific hypothesis was that the establishment of composite coating could tailor Ti interfacial organization for multimodal antibacterial performance. Benefiting from its interfacial organization, the resulting coating achieved well-defined surface wettability and interfacial catalytic activity, which further regulated the interfacial interaction with bacteria. Such coating exhibited prominent physical and chemical dual bactericidal activities, which might be realized via multiple possible pathways including the inhibition of bacterial adhesion, potential mechanical nano-cutting effect and induction of intracellular oxidative stress. In vitro assay revealed that the coating had ca. 100% bactericidal efficiency against E. coli and 99.54% against S. aureus, while in vivo tissue infection model showed a 97.21% antibacterial rate for the coating against S. aureus. It not only effectively suppressed the deterioration of implant-associated infection, but also promoted the integration between implant and host tissue. Moreover, this modified implant displayed satisfactory cytocompatibility and hemocompatibility, and was expected to develop into a new-type efficient and safe anti-infective implant material, demonstrating broad clinical application prospect in the field of biomedical implant. Conceptually, this work presented a passive and external-stimulus-free interfacial antibacterial strategy and provided theoretical basis and technical strategy for the innovative surface antibacterial modification of implantable medical device.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.