Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

Simultaneous quantification of remimazolam, midazolam, 1'-hydroxymidazolam, and dexmedetomidine in rat plasma by LC-MS/MS: application to biological samples and partial validation in ECMO-derived plasma.

Rina Kakuba, Yuhki Sato, Yu Fujii, Yuka Nagatsuka, Takuya Abe, Yutaka Fujii

Department of Pharmaceutical Sciences, Faculty of Pharmacy and Pharmaceutical Sciences, Fukuyama University, Fukuyama-shi, Hiroshima, Japan. · Department of Pharmaceutical Sciences, Faculty of Pharmacy and Pharmaceutical Sciences, Fukuyama University, Fukuyama-shi, Hiroshima, Japan. Electronic address: s-yuhki@fukuyama-u.ac.jp.

Key points

From the paper's conclusion
  • The objective of this study was to develop and validate a sensitive reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of remimazolam (RMZ), midazolam (MDZ), 1'-hydroxymidazolam (1'-OH-MDZ), and dexmedetomidine (DEX) in rat plasma, in compliance with current FDA bioanalytical guidelines.

Abstract

The objective of this study was to develop and validate a sensitive reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of remimazolam (RMZ), midazolam (MDZ), 1'-hydroxymidazolam (1'-OH-MDZ), and dexmedetomidine (DEX) in rat plasma, in compliance with current FDA bioanalytical guidelines. Protein precipitation with esterase inhibition was optimized for 50 μL of rat plasma. Calibration ranges were established to cover the expected in vivo concentrations in pharmacokinetic studies. Full validation was conducted using normal rat plasma, and assay performance was further confirmed by partial validation using extracorporeal membrane oxygenation (ECMO)-derived plasma. The method achieved lower limits of quantification (LLOQs) of 10 ng/mL for RMZ and MDZ, 5.0 ng/mL for 1'-OH-MDZ, and 1.0 ng/mL for DEX. Calibration curves were linear (r2 ≥ 0.99) using weighted (1/x or 1/x2) regression. Within- and between-run accuracy and precision met acceptance criteria (≤15%, and ≤ 20% at the LLOQ). Extraction recovery was consistent, and matrix effects were adequately controlled. RMZ stability was improved through the combined use of sodium fluoride, EDTA-2 K, cooling, and acidification during sample handling. The applicability of the method was demonstrated by quantifying all analytes in plasma samples obtained from rats following intravenous administration. This assay enables simultaneous quantification of clinically relevant sedatives and an active metabolite in small-volume rat samples and may facilitate future pharmacokinetic investigations in preclinical ECMO models.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Simultaneous quantification of remimazolam, midazolam, 1'-hydroxymidazolam, and dexmedetomidine in rat plasma by LC-MS/MS: application to biological samples and partial validation in ECMO-derived plasma — Science Skim