Development of combined bio-RP-HPLC-UV and UHPLC-ELSD methods for quantitation of mRNA-LNP content before and after size-exclusion chromatography.
Ting Sun, Qi Wu, Xueli Liu, Zhanlei Xing, Lin Shi, Feizi Hu, Yang Sun, Yafeng Wang
Institute of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China; Hebei Institute for Drug and Medical Device Control, Shijiazhuang, Hebei, 050200, China. · Tianjin University HAIHE Hospital, Tianjin, 300350, China. Electronic address: wq572004@163.com.
Key points
From the paper's conclusion- A 2/6-port valve-switching splitting device was installed upstream of the UHPLC-ELSD detector to prevent rapid detector contamination induced by direct injection of complex mRNA-LNP formulation matrices and substantially reduce instrument-maintenance frequency.
Abstract
Following the COVID-19 pandemic, mRNA vaccines have been widely deployed, with lipid nanoparticles (LNPs) serving as the prevailing delivery vehicles for mRNA vaccines. Separation and quantitative determination of mRNA and LNP lipid components have therefore attracted considerable attention. Reported mRNA assays suffer from several limitations, including interferences originating from metallic instrument components and complex formulation matrices, insufficient resolution, and prolonged elution durations. Existing analytical approaches for LNP lipid quantification usually involve labor-intensive sample pretreatment and fail to eliminate matrix interferences. Even reported methods capable of simultaneous measurement of nucleic acids and lipids still exhibit deficiencies in resolution and sensitivity. Herein, an integrated analytical platform combining Bio-RP-HPLC-UV and UHPLC-ELSD was established. A biocompatible inert liquid-chromatography system was adopted for mRNA quantification to mitigate adsorption and carry-over effects commonly observed in conventional stainless-steel systems, while chromatographic conditions were optimized to shorten analysis time. A 2/6-port valve-switching splitting device was installed upstream of the UHPLC-ELSD detector to prevent rapid detector contamination induced by direct injection of complex mRNA-LNP formulation matrices and substantially reduce instrument-maintenance frequency. Mobile-phase compositions were further optimized to improve resolution and sensitivity for LNP lipid detection. The validated workflow exhibited favorable precision and excellent linearity (R > 0.9990). The recovery of the mRNA quantification method ranged from 87.89% to 100.31%, and the mean recoveries of the four LNP lipids at three concentration levels varied between 99.52% and 102.46%, guaranteeing assay accuracy. Furthermore, this integrated platform was applied to characterize mRNA-LNP samples before and after size-exclusion-chromatography (SEC) purification. Correlation analysis was performed among mRNA contents, drug-to-lipid ratios, and particle-size data acquired by high-throughput dynamic light scattering (DLS). Results from method-validation experiments and testing of three batches of samples demonstrated that the proposed platform enables simultaneous quantification of mRNA and lipids in mRNA-LNP formulations and multi-attribute parameter correlation verification throughout the SEC purification procedure. Satisfactory inter-batch consistency was achieved across three production batches. This work provides technical support for constructing a facile and practicable quality-evaluation system for mRNA-LNP vaccine formulations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dilution mode acts as a critical process parameter that reprograms lipid nanoparticle assembly and in vivo mRNA delivery.Journal of controlled release : official journal of the Controlled Release Society · 2026
- Single-Particle Multiparametric Microscopy Reveals Structural, Size, and Payload Heterogeneity in mRNA-Loaded Lipid NanoparticlesACS Nano · 2025
- Critical Evaluation of Key Methods for RNA Quantification.International journal of molecular sciences · 2026
- Critical chemistry manufacturing and controls considerations for mRNA lipid nanoparticle translation.Discover nano · 2026
- Colloidal Light Scattering Distorts Fluorometric Quantification of mRNA in Lipid Nanoparticles.Current issues in molecular biology · 2026
- PINPOINT enables non-destructive nanoscopic quality control of individual lipid nanoparticles and their mRNA cargo.bioRxiv : the preprint server for biology · 2026