Journal of biomechanics

Cervical biomechanical responses to parachute opening shock: effects of shock magnitude and initial body orientation.

Shuanghui Cao, Siqi Deng, Qingbo Dou, Tao Suo

National Elite Institute of Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Beilin District, Xi'an, Shaanxi 710072, PR China. Electronic address: drcsh@mail.nwpu.edu.cn. · School of Aeronautics, Northwestern Polytechnical University, 127 West Youyi Road, Beilin District, Xi'an, Shaanxi 710072, PR China. Electronic address: denceq@mail.nwpu.edu.cn.

Key points

From the paper's conclusion
  • The effects of POS magnitude and initial body orientation on cervical kinematics, regional loading, and local tissue biomechanical responses were subsequently investigated.

Abstract

Injuries associated with parachute opening shock (POS) are a major form of trauma related to parachuting and remain an important concern in aerospace medicine. A full human body finite element model of POS incorporating a three-point harness system was developed, and its global dynamic response was evaluated using data from a physical POS test conducted with a Hybrid Ⅲ dummy. The first head acceleration peaks of the simulated and experimental responses were similar in magnitude and time to peak. The effects of POS magnitude and initial body orientation on cervical kinematics, regional loading, and local tissue biomechanical responses were subsequently investigated. The results indicated that POS induced nonuniform segmental cervical flexion and distinct loading patterns across different cervical regions. Increasing the POS magnitude generally increased cervical loads, intervertebral differential flexion, and tensile strains in the posterior cervical ligaments, whereas peak stress in individual vertebrae showed segmental variations. Changes in initial body orientation substantially altered the loading patterns of the middle and lower cervical spine by modifying harness load distribution and trunk motion. This study establishes a human body finite element framework that incorporates harness load transfer to reveal how POS magnitude and initial body orientation redistribute cervical loading from global trunk motion to segmental deformation and local tissue responses.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Cervical biomechanical responses to parachute opening shock: effects of shock magnitude and initial body orientation — Science Skim