Journal of biomechanics

Mechanism of activation-dependent shift in the human soleus fascicle force-length relationship studied using a 3D finite element model.

Katherine R Knaus

Department of Mechanical Engineering, Colorado School of Mines, United States. Electronic address: katherine.knaus@mines.edu.

Key points

From the paper's conclusion
  • A rightward shift with decreasing activation in optimal fascicle length where peak active forces occurred emerged from complex 3D architecture, despite a similar shift being absent in the force-length relationship of the underlying muscle material model.

Abstract

We investigated the force-length relationship of human soleus at varying activation levels to examine effects of complex architecture and aponeuroses on fascicle lengths at which peak active muscle forces occur. Using a three-dimensional (3D) finite element (FE) model, previously validated with magnetic resonance imaging (MRI), we simulated soleus muscle excursion while prescribing different activations ranging from passive to fully active. FE simulations demonstrated peaks in average active force-length relationships of fascicles at relative lengths of 1.06, 1.07, 1.08, and 1.09 at 100%, 75%, 50%, and 25% activation, respectively. A rightward shift with decreasing activation in optimal fascicle length where peak active forces occurred emerged from complex 3D architecture, despite a similar shift being absent in the force-length relationship of the underlying muscle material model. This emergent behavior demonstrates that muscle and aponeurosis architectural complexity present in the model contributes to activation-dependent shifts in optimal muscle length, rather than purely subcellular mechanisms not represented in the model's muscle material behavior. Soleus simulations also revealed significant inter-fascicle heterogeneity in lengths and pennation angles which increased with activation, demonstrating that the common one-dimensional conceptual model of a muscle-tendon unit (MTU) oversimplifies the mechanics of complex multipennate muscles when 'subtracting out' effects of tendon compliance to characterize active force-length. The study highlights the importance of considering 3D architectural complexity when scaling muscle mechanics across species from animal to humans, particularly the soleus, as the simplified structure in small mammals may not capture effects of intramuscular aponeuroses on active muscle mechanics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Mechanism of activation-dependent shift in the human soleus fascicle force-length relationship studied using a 3D finite element model — Science Skim