Comparing Theia3D software versions for gait kinematics in typically developing children.
Joel Kearney, Henrike Greaves, Mark A Robinson, Gabor J Barton, Thomas D O'Brien, Karl C Gibbon, Richard J Foster
Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UK. Electronic address: J.S.Kearney@2023.ljmu.ac.uk. · Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UK; Alder Hey Children's NHS Foundation Trust, Liverpool, UK.
Key points
From the paper's conclusion- These findings demonstrate that software version does influence motion capture kinematics.
Abstract
Markerless motion capture systems such as Theia3D offer an alternative to traditional marker-based approaches for measuring gait kinematics. As the underlying algorithms continue to evolve, successive software updates may introduce differences in kinematic outputs. However, the extent of these differences is not well known. The purpose of this study was to quantify inter-version differences in Theia3D-derived gait kinematics in typically developing children. Sixteen typically developing children completed five barefoot walking trials at a self-selected speed. Video data were processed using three versions of Theia3D (v2022.1.0.2309, v2023.1.03161 and v2024.1.24). Inter-version differences were assessed across joints and planes of motion using one-dimensional Statistical Parametric Mapping (1D-SPM) repeated measures ANOVA, with planned pairwise comparisons between sequential releases. Significant differences were identified across all joints and planes of motion. The largest differences were observed between v2022 and v2023, with smaller and more localised differences between v2023 and v2024. Mean differences were generally below 6°, with larger deviations observed in the transverse plane at the ankle and foot and in the sagittal plane at the trunk, pelvis and hip. Differences were not consistent across versions, with some angles demonstrating patterns that reverted towards earlier outputs. These findings demonstrate that software version does influence motion capture kinematics. While differences are small at some joint levels, there is potential for software version to influence interpretation in certain contexts, particularly in longitudinal assessments. Obligatory reporting of software version and data reprocessing are recommended when using markerless systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The effect of camera configuration on multi-camera markerless motion capture for biomechanical analysis.Journal of biomechanics · 2026
- Lighting and clothing effects on Theia3D markerless joint-angle waveforms during walking.Journal of biomechanics · 2026
- Comparison of Joint Kinematics and Spatiotemporal Gait Parameters Between Markerless and Marker-Based Motion Capture in a Large Knee Osteoarthritis Cohort.Annals of biomedical engineering · 2026
- Markerless motion capture for running: validity and reliability of whole-body, joint, and muscle kinematicsJournal of Biomechanics · 2025
- Agreement of markerless and marker-based joint kinetics in team sport-specific change-of-direction movementsScientific Reports · 2026
- AI-Enabled Markerless Motion Capture for Gait Analysis and Rehabilitation: A Narrative Review.Bioengineering (Basel, Switzerland) · 2026