A cubic Hunt-Crossley contact law and subject-specific calibration improve ground reaction force prediction in musculoskeletal walking simulations.
Francesco Piqué, Matteo Bianchi, Alessio Artoni
Department of Information Engineering, Università di Pisa, Pisa, Italy. Electronic address: francesco.pique@ing.unipi.it. · Department of Information Engineering, Università di Pisa, Pisa, Italy; Research Center "E. Piaggio", Università di Pisa, Pisa, Italy. Electronic address: matteo.bianchi@unipi.it.
Key points
From the paper's conclusion- We address this gap on three fronts.
Abstract
Predictive musculoskeletal (MSK) simulations of walking are increasingly used to inform clinical and device-design decisions, yet their accuracy in reproducing ground reaction forces (GRF) remains limited. A contributing factor that has received little scrutiny is the foot-ground contact model and its parameters. We address this gap on three fronts. First, we revisit the Hunt-Crossley contact formulation against in vivo heel-pad impact data and show that the standard Simbody Hertzian elastic law cannot capture the biphasic mechanical behavior of the heel pad: replacing the 3/2 indentation exponent with a cubic one yields a markedly better fit to the experimental force-deformation characteristic. Second, we embed six of these modified contact spheres in an OpenSim MSK model and identify their mechanical parameters through a multiobjective optimization against experimental contact wrenches over six gait trials, a subject-specific calibration step that has received limited attention in recent OpenSim-based studies. Third, we show that allowing the prescribed lower-limb kinematics to vary within bounds consistent with both motion-capture measurement errors and inverse-kinematics errors is essential to recovering accurate GRF: the joint identification of contact parameters and kinematics yields normalized root-mean-squared errors below 7.1% across all six components of the contact wrench. Repeating the identification with the standard Hunt-Crossley model under the same pipeline produces errors approximately twice as large, confirming that the cubic contact law, not the identification procedure alone, drives the improvement. A leave-one-out cross-validation indicates that the identified parameters remain stable across trials, supporting the pipeline as a subject-specific proof of concept.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integration of a smooth mesh-based contact pressure model into tracking and predictive simulationsbioRxiv · 2026
- Generic Versus Personalized Foot-Ground Contact Models for Predictive Simulations of Walking: Is Personalization Worth the Effort?Annals of biomedical engineering · 2026
- Extending Musculoskeletal Modelling Validation Beyond Gait: Knee Loading and Kinematics During Daily ActivitiesbioRxiv · 2026
- Predicting Knee Contact Forces During Walking From Monocular Video and Demographic Information.Annals of biomedical engineering · 2026
- Benchmarking the predictive capability of human gait simulationsPLoS Computational Biology · 2025
- Simulating human foot mechanics during walking based on an anatomically detailed forward dynamic finite element modelAnnals of Biomedical Engineering · 2026