Journal of the American College of Radiology : JACR

AI Latency, Report Turnaround Time, and Adoption in a Multi-Vendor AI Ecosystem: A Multi-Site Observational Study.

Sergey Morozov, Natalie Heracleous, Diana Korka, Cyril Thouly, Benoît Dufour, Octave Novarina, Benoît Rizk

General Manager, Medlogic, Brussels, Belgium. Electronic address: dr.morozov.sergey@gmail.com. · Senior Researcher, 3R Swiss Imaging Network, Sion, Switzerland.

Observational

Key points

From the paper's conclusion
  • Active AI adoption was 91.4% (53/58), with 66% (35/53) reporting regular use. Median total latency was 2.06 minutes [interquartile range 1.74-3.05], 72% of which attributable to data routing. The "Too Late" rate (AI result arriving after report finalization) was 7.2% overall, ranging from 3.0% for knee MRI to 13.2% for chest CT. After adjustment for radiologist (linear mixed-effects models), AI availability was associated with lower median TAT for trauma radiography (-26%) and knee MRI (-18%; both p<0.001); brain volumetry MRI showed no significant change (+9.2%; p=0.33). In exploratory analysis, NPS declined for chest CT (+38 to -3) and aorta CT (+22 to -25), nominally significant before multiple-comparison correction.

Abstract

OBJECTIVE: To evaluate infrastructure latency, workflow, and radiologist sentiment across a 4.5-year, multi-vendor AI implementation program in a 20-center outpatient radiology network. METHODS: Three retrospective cohorts: a technical cohort (96,874 examinations; Sep 2023-Sep 2025) for PACS-to-PACS latency and temporal alignment of 10 AI tools from 7 vendors; a report turnaround time (TAT) analysis cohort (20,909 examinations; Mar-Aug 2025) comparing TAT between AI-available and concurrent non-AI workflows by Mann-Whitney U; and a survey cohort (58 radiologists; two waves 2025) for adoption, Likert-scale perceptions, and Net Promoter Score (NPS). RESULTS: Active AI adoption was 91.4% (53/58), with 66% (35/53) reporting regular use. Median total latency was 2.06 minutes [interquartile range 1.74-3.05], 72% of which attributable to data routing. The "Too Late" rate (AI result arriving after report finalization) was 7.2% overall, ranging from 3.0% for knee MRI to 13.2% for chest CT. After adjustment for radiologist (linear mixed-effects models), AI availability was associated with lower median TAT for trauma radiography (-26%) and knee MRI (-18%; both p<0.001); brain volumetry MRI showed no significant change (+9.2%; p=0.33). In exploratory analysis, NPS declined for chest CT (+38 to -3) and aorta CT (+22 to -25), nominally significant before multiple-comparison correction. DISCUSSION: Multi-vendor AI at scale was associated with measurable TAT gains in high-volume modalities. Infrastructure latency, not algorithm speed, was the primary barrier to clinical utility. At ∼23-25% annualized cost of one radiologist full-time equivalent (FTE) salary, the program generated 0.69 FTE of capacity through trauma radiography alone (0.46 FTE after radiologist-adjusted sensitivity analysis).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

AI Latency, Report Turnaround Time, and Adoption in a Multi-Vendor AI Ecosystem: A Multi-Site Observational Study — Science Skim