AI Latency, Report Turnaround Time, and Adoption in a Multi-Vendor AI Ecosystem: A Multi-Site Observational Study.
Sergey Morozov, Natalie Heracleous, Diana Korka, Cyril Thouly, Benoît Dufour, Octave Novarina, Benoît Rizk
General Manager, Medlogic, Brussels, Belgium. Electronic address: dr.morozov.sergey@gmail.com. · Senior Researcher, 3R Swiss Imaging Network, Sion, Switzerland.
Key points
From the paper's conclusion- Active AI adoption was 91.4% (53/58), with 66% (35/53) reporting regular use. Median total latency was 2.06 minutes [interquartile range 1.74-3.05], 72% of which attributable to data routing. The "Too Late" rate (AI result arriving after report finalization) was 7.2% overall, ranging from 3.0% for knee MRI to 13.2% for chest CT. After adjustment for radiologist (linear mixed-effects models), AI availability was associated with lower median TAT for trauma radiography (-26%) and knee MRI (-18%; both p<0.001); brain volumetry MRI showed no significant change (+9.2%; p=0.33). In exploratory analysis, NPS declined for chest CT (+38 to -3) and aorta CT (+22 to -25), nominally significant before multiple-comparison correction.
Abstract
OBJECTIVE: To evaluate infrastructure latency, workflow, and radiologist sentiment across a 4.5-year, multi-vendor AI implementation program in a 20-center outpatient radiology network. METHODS: Three retrospective cohorts: a technical cohort (96,874 examinations; Sep 2023-Sep 2025) for PACS-to-PACS latency and temporal alignment of 10 AI tools from 7 vendors; a report turnaround time (TAT) analysis cohort (20,909 examinations; Mar-Aug 2025) comparing TAT between AI-available and concurrent non-AI workflows by Mann-Whitney U; and a survey cohort (58 radiologists; two waves 2025) for adoption, Likert-scale perceptions, and Net Promoter Score (NPS). RESULTS: Active AI adoption was 91.4% (53/58), with 66% (35/53) reporting regular use. Median total latency was 2.06 minutes [interquartile range 1.74-3.05], 72% of which attributable to data routing. The "Too Late" rate (AI result arriving after report finalization) was 7.2% overall, ranging from 3.0% for knee MRI to 13.2% for chest CT. After adjustment for radiologist (linear mixed-effects models), AI availability was associated with lower median TAT for trauma radiography (-26%) and knee MRI (-18%; both p<0.001); brain volumetry MRI showed no significant change (+9.2%; p=0.33). In exploratory analysis, NPS declined for chest CT (+38 to -3) and aorta CT (+22 to -25), nominally significant before multiple-comparison correction. DISCUSSION: Multi-vendor AI at scale was associated with measurable TAT gains in high-volume modalities. Infrastructure latency, not algorithm speed, was the primary barrier to clinical utility. At ∼23-25% annualized cost of one radiologist full-time equivalent (FTE) salary, the program generated 0.69 FTE of capacity through trauma radiography alone (0.46 FTE after radiologist-adjusted sensitivity analysis).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of AI-Triaged Worklists and AI-Assisted Report Generation on Radiology Turnaround Times: Prospective Real-World Study.Journal of medical Internet research · 2026
- Artificial intelligence triages chest radiographs: Optimising diagnostic workflow efficiency in hospital settings.Radiography (London, England : 1995) · 2026
- Agentic artificial intelligence in radiology workflow: from image interpretation to report quality control.Frontiers in medicine · 2026
- Predictive and operational artificial intelligence in emergency radiology for early risk stratification in acute care settings: a scoping review.European radiology · 2026
- AI as Core Infrastructure in Radiology: Moving Beyond Pilots to Operational Excellence.Journal of imaging informatics in medicine · 2026
- Predicting the Value of Radiology Artificial Intelligence Applications: Large-Scale Predeployment Evaluation of a Portfolio of ModelsAmerican Journal of Roentgenology · 2026