科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Journal of the American College of Radiology : JACR2026-09-22

Motion-Related Repeat MRI Sequences in a High-Volume Health System: Operational Burden and Heterogeneous Diagnostic Benefit.

Siddhant Dogra, Luke A Ginocchio, Andrew C McClelland, Matthew G Young, Anthony Yang, Jason Wei, Sherif B Elsherif, Nihal Patel, Wendy Huang, Hoi Cheung Zhang, Elena A Kaye, Mahesh B Keerthivasan, Thomas Mulholland, Silvia Arroyo Camejo, Fabian Wagner, Rainer Schneider, Yvonne W Lui, Michael P Recht, Hersh Chandarana

一句话结论 · In one sentence

Among 85,349 MRI examinations, 4,072 (4.8%) included at least one repeated sequence. Repeat frequency was highest in pediatrics (9.9%) and lowest in breast MRI (3.5%). In the brain MRI study, 87 baseline-repeat pairs from 77 patients were evaluated. Repeat acquisition significantly improved image quality and diagnostic confidence across all metrics (all p<0.001). 19.5% of repeat sequences did not improve. Improvement declined with greater elapsed examination time. In the MRCP study, 30 baseline-repeat pairs from 27 patients were evaluated. Repeat acquisition did not significantly improve image quality or diagnostic confidence, and both readers would have requested another repeat for half of repeated acquisitions.

原始摘要(英文原文)· Original abstract
OBJECTIVE: To quantify the operational burden of motion-related repeat MRI sequences across a high-volume health system and evaluate whether repeat acquisitions improve image quality and confidence in brain MRI and magnetic resonance cholangiopancreatography (MRCP). METHODS: This retrospective study analyzed six months of MRI examinations on scanners with sequence-level analytics. Examinations with technologist-labeled repeated sequences were identified. Brain MRI and MRCP baseline-repeat pairs were evaluated by four and two readers, respectively. Readers scored image quality and diagnostic confidence and indicated whether another repeat would be requested. Scores were compared using linear mixed-effects models with patient-level random intercepts. RESULTS: Among 85,349 MRI examinations, 4,072 (4.8%) included at least one repeated sequence. Repeat frequency was highest in pediatrics (9.9%) and lowest in breast MRI (3.5%). In the brain MRI study, 87 baseline-repeat pairs from 77 patients were evaluated. Repeat acquisition significantly improved image quality and diagnostic confidence across all metrics (all p<0.001). 19.5% of repeat sequences did not improve. Improvement declined with greater elapsed examination time. In the MRCP study, 30 baseline-repeat pairs from 27 patients were evaluated. Repeat acquisition did not significantly improve image quality or diagnostic confidence, and both readers would have requested another repeat for half of repeated acquisitions. DISCUSSION: Motion-driven repeat MRI sequences impose measurable operational burden, but diagnostic yield varies substantially by anatomic region and sequence type. Brain MRI repeats generally improved image quality and diagnostic confidence, whereas MRCP repeats showed limited benefit. These findings support sequence-level tracking to guide targeted motion-mitigation strategies and reduce low-value repeat imaging.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Motion-Related Repeat MRI Sequences in a High-Volume Health System: Operational Burden and Heterogeneous Diagnostic Benefit. — 科研速览 Science Skim