Journal of clinical lipidology

LDL-C equation disagreement as a threshold-integrity flag for orthogonal lipid confirmation.

Ronald Doku, Nana Yaw A Osafo, John Kwagyan, William M Southerland

Howard University College of Medicine, Washington D.C., USA. Electronic address: ronald.doku@howard.edu. · Howard University College of Medicine, Washington D.C., USA.

Key points

From the paper's conclusion
  • LDL-C equation disagreement is a threshold-integrity flag, not proof that any equation is wrong. When equations disagree near a treatment goal, clinicians should avoid treating the LDL-C threshold result as unqualified and consider orthogonal confirmation, preferably ApoB, when particle burden is the clinical question.

Abstract

BACKGROUND: Multiple low-density lipoprotein cholesterol (LDL-C) equations can be applied to every standard lipid panel. Disagreement across a treatment threshold may indicate unstable classification. OBJECTIVE: To test LDL-C equation disagreement as a calculation-only threshold-integrity flag and as a trigger for orthogonal lipid confirmation. METHODS: We analyzed decontaminated All of Us lipid panels with same-day standard lipids and direct homogeneous LDL-C, recognizing that direct LDL-C is a clinical reference assay rather than beta-quantification. Friedewald, Sampson/National Institutes of Health (NIH), and Martin-Hopkins were evaluated at LDL-C thresholds of 70, 100, and 130 mg/dL; 55 mg/dL was added in the temporal audit. The 3-equation disagreement flag was compared against triglyceride (TG)-based reflex rules. Medical Information Mart for Intensive Care IV (MIMIC-IV) was used for external stress testing. RESULTS: Equation agreement identified a high-stability majority: in the primary All of Us cohort, equations agreed for 86% to 92% of panels with 92% to 95% threshold accuracy. In the temporal audit, future clean panels showed 3-equation disagreement in 10.2%, 11.4%, 9.2%, and 5.8% of rows at LDL-C thresholds of 55, 70, 100, and 130 mg/dL. Disagreement-subgroup accuracy was lower for all 3 equations. The 3-equation straddle outperformed TG ≥200 mg/dL for detecting apparent at-goal discordance at all 4 thresholds. Sparse apolipoprotein B (ApoB) analyses supported ApoB as an independent witness. CONCLUSION: LDL-C equation disagreement is a threshold-integrity flag, not proof that any equation is wrong. When equations disagree near a treatment goal, clinicians should avoid treating the LDL-C threshold result as unqualified and consider orthogonal confirmation, preferably ApoB, when particle burden is the clinical question.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers