Pulsed Field Ablation of the Left Atrial Appendage Before Mechanical Closure to Reduce Peri-Device Leak (STUN-AF).
John R Power, Devi G Nair, Shephal K Doshi, Mohit K Turagam, Mohamed Mraiyan, Ganesh Nair, Brandon Doty, Alette Laughton,
Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York, USA. · St Bernards Medical Center & Arrhythmia Research Group, Jonesboro, Arkansas, USA.
Key points
From the paper's conclusion- PFA of the LAA has potential to reduce LAA patency during device-based LAAC.
Abstract
BACKGROUND: Left atrial appendage (LAA) closure (LAAC) is plagued by late peri-device leak. We posited that appendage contraction prevents full LAA seal, so conversely, LAA stunning with pulsed field ablation (PFA) of the LAA (left atrial appendage ablation [LAAA]) might promote rapid appendage thrombosis/obliteration. OBJECTIVES: This study aims to assess the impact of LAAA during concomitant procedures on eliminating leaks. METHODS: At 3 centers, consecutive patients undergoing concomitant PFA and LAAC also underwent LAAA or did not undergo LAAA, at operator discretion. Initial (∼3-4 months) (29% transesophageal echocardiography/71% computed tomography) and 12-month imaging were compared with a primary composite outcome of LAA patency, defined as either detectable flow into the LAA or evidence of echo-free space/contrast medium behind the device. RESULTS: Among 317 total patients undergoing PFA and LAAC, including 222 patients who underwent LAAA and 95 who did not (control patients), all underwent initial imaging and 126 reached 12-month imaging follow-up. Device compression was 28% with LAAA vs 25% without LAAA (P < 0.001). Implantation success was 100%. The periprocedural adverse event rate was 2% in both groups. The primary composite outcome of LAA patency was significantly reduced with LAAA vs no-LAAA, both at 3-4 months (29% vs 64%; P < 0.001) and at 12 months (4% vs 42%; P < 0.001). Device-related thrombus rates were low and similar (2.3% vs 3.2%; P = 0.7). A validation subset including only patients with alternating LAAA assignment (LAAA: n = 59; no-LAAA: n = 63) again revealed that LAAA was associated with reduced LAA patency (3-4 months: 34% vs 51%; P = 0.06; 12 months: 8% vs 36%; P = 0.2). Final LAA e' velocity was significantly different between groups (17 ± 7 vs 34 ± 16 cm/s; P < 0.001), with higher velocity associated with LAA patency (P < 0.001). CONCLUSIONS: PFA of the LAA has potential to reduce LAA patency during device-based LAAC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left atrial appendage stunning during pulse-field ablation using a variable-loop irrigated circular catheterEuropean Heart Journal · 2026
- Intraprocedural left atrial appendage thrombus formation during percutaneous left atrial appendage closure: A case report.Journal of cardiology cases · 2026
- The perspective of combining pulsed field ablation and left atrial appendage closure.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Left Atrial Appendage Electrical Isolation Reduces Residual Patency After Device Closure in Patients With Persistent Atrial FibrillationJournal of the American Heart Association · 2026
- Percutaneous Closure of a Left Atrial Pseudoaneurysm After Left Atrial Appendage Closure.JACC. Case reports · 2026
- Feasibility, procedural efficiency, and early imaging outcomes of concomitant pulsed field ablation and left atrial appendage closure: a prospective single-centre studyEP Europace · 2026