Failing Fontan Circulation Bridged to Heart Transplantation With a Surgically Implanted Microaxial Flow Pump.
Bernd Panholzer, Gregor Warnecke, Anselm Uebing, Arne Martin Eide, Tim Attmann
Department of Cardiac Surgery, University Hospital Schleswig-Holstein, Kiel, Germany. Electronic address: Bernd.panholzer@uksh.de. · Department of Cardiac Surgery, University Hospital Schleswig-Holstein, Kiel, Germany.
Key points
From the paper's conclusion- Patients with a failing systemic ventricle in Fontan circulation can be successfully bridged to heart transplant by insertion of a microaxial flow pump.
Abstract
An 18-year-old male patient with Fontan circulation was admitted to our institution with progressive cardiac decompensation. Because of his severely impaired systolic function, he had previously been listed for heart transplantation. Following admission, he rapidly developed cardiogenic shock, necessitating cardiopulmonary resuscitation and intubation. After implantation of a microaxial flow pump through the right subclavian artery, hemodynamics and respiration stabilized quickly; notably, the patient was extubated on the first postoperative day. Sixteen days thereafter, heart transplantation was performed successfully. TAKE-HOME MESSAGE: Patients with a failing systemic ventricle in Fontan circulation can be successfully bridged to heart transplant by insertion of a microaxial flow pump.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transinnominate Microaxial Flow Pump Placement in a Patient With Failing Fontan Circulation as Bridge to Transplantation.JACC. Case reports · 2026
- Heart transplant in an adult patient with dysfunctional Fontan circulation at a high-complexity cardiovascular center in Peru: A case report.Archivos peruanos de cardiologia y cirugia cardiovascular · 2026
- Fontan Failure: Current State of the Art in Mechanical Circulatory Support and Transplantation.Children (Basel, Switzerland) · 2026
- Fontan pump: Advanced preclinical development.The Journal of thoracic and cardiovascular surgery · 2026
- Role of digital health in the personalized management of heart failure due to Fontan failure: a case report.European heart journal. Case reports · 2026
- Berlin heart EXCOR® implantation for Fontan failure in right-sided heterotaxy with ventricular septal protuberance: autopsy case report.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026