JACC. Case reports

Failing Fontan Circulation Bridged to Heart Transplantation With a Surgically Implanted Microaxial Flow Pump.

Bernd Panholzer, Gregor Warnecke, Anselm Uebing, Arne Martin Eide, Tim Attmann

Department of Cardiac Surgery, University Hospital Schleswig-Holstein, Kiel, Germany. Electronic address: Bernd.panholzer@uksh.de. · Department of Cardiac Surgery, University Hospital Schleswig-Holstein, Kiel, Germany.

Key points

From the paper's conclusion
  • Patients with a failing systemic ventricle in Fontan circulation can be successfully bridged to heart transplant by insertion of a microaxial flow pump.

Abstract

An 18-year-old male patient with Fontan circulation was admitted to our institution with progressive cardiac decompensation. Because of his severely impaired systolic function, he had previously been listed for heart transplantation. Following admission, he rapidly developed cardiogenic shock, necessitating cardiopulmonary resuscitation and intubation. After implantation of a microaxial flow pump through the right subclavian artery, hemodynamics and respiration stabilized quickly; notably, the patient was extubated on the first postoperative day. Sixteen days thereafter, heart transplantation was performed successfully. TAKE-HOME MESSAGE: Patients with a failing systemic ventricle in Fontan circulation can be successfully bridged to heart transplant by insertion of a microaxial flow pump.