JACC. Case reports

Occult Patent Foramen Ovale Causing Severe Refractory Hypoxemia After Acute Type A Aortic Dissection Repair.

Sanjay Chaubey, Vaidehi Mendpara, Mohammad Alqahtani, Nikolaos J Skubas, Marc Gillinov, Miralem Pasic

Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic, Cleveland, Ohio, USA. · Department of Internal Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Key points

From the paper's conclusion
  • Persistent refractory hypoxemia after acute type A aortic dissection repair is not always pulmonary in origin.

Abstract

BACKGROUND: After surgery for acute type A aortic dissection, pulmonary function can be reduced because of several possible causes. It is necessary to identify the main cause. CASE SUMMARY: A patient experienced refractory hypoxemia following type A aortic dissection repair. Despite proper respiratory and inotropic support, and near-normal chest imaging, severe hypoxia persisted. Echocardiography revealed an occult patent foramen ovale (PFO) with significant right-to-left shunting, driven by positive-pressure mechanical ventilation and elevated right-sided cardiac pressures. Percutaneous transcatheter closure immediately improved oxygenation, enabling successful ventilator weaning. DISCUSSION: Occult PFO should be suspected in unexplained postsurgical hypoxemia. Early echocardiographic evaluation and prompt percutaneous closure can rapidly reverse hypoxia, preventing prolonged mechanical ventilation and secondary complications. TAKE-HOME MESSAGES: Persistent refractory hypoxemia after acute type A aortic dissection repair is not always pulmonary in origin. Occult PFO should be suspected and early echocardiographic confirmation with prompt PFO closure can produce immediate clinical improvement.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers