Stroke After Surgical Left Atrial Appendage Clip With Residual Neck Thrombus: Transcatheter Plug Closure.
Charbel Noujaim, Karen Jabbour, Mohammad Abbasi, Rhonda L Miyasaka, Bo Xu, Pasquale Santangeli, Wael A Jaber, Mohamed H Kanj
Department of Cardiovascular Medicine, Cleveland Clinic Foundation, Cleveland, Ohio, USA. Electronic address: https://twitter.com/charbelnoujaim. · Department of Cardiovascular Medicine, Cleveland Clinic Foundation, Cleveland, Ohio, USA. Electronic address: https://twitter.com/karen__jabbour.
Key points
From the paper's conclusion- Plug occlusion performed with cerebral embolic protection can convert incomplete surgical exclusion to complete closure.
Abstract
BACKGROUND: Incomplete left atrial appendage clip closure is a recognized complication and may increase thromboembolic risk. CASE SUMMARY: A 72-year-old woman with persistent atrial fibrillation presented with a left middle cerebral artery stroke while on apixaban. History included mitral valve repair with epicardial left atrial appendage clip and AV-junction ablation with a leadless pacemaker. Local transesophageal echocardiogram (TEE) reported complete ligation without thrombus; cardiac computed tomography at our institution demonstrated incomplete ligation with a narrow residual ostium and an 11 × 6 mm thrombus. With Sentinel cerebral embolic protection, intraprocedural TEE identified a 6 × 5 mm residual communication. Single transseptal access (Agilis sheath, VersaCross RF wire) permitted traversal of the neck; a 12-mm Amplatzer Vascular Plug II was implanted. TEE and angiography confirmed complete seal; recovery was uneventful. TAKE-HOME MESSAGES: Computed tomography and TEE should confirm exclusion before stopping anticoagulation after clip ligation. Plug occlusion performed with cerebral embolic protection can convert incomplete surgical exclusion to complete closure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Residual Surgical Left Atrial Appendage Leaks: Thromboembolic Risk and Anatomy-Tailored Percutaneous Closure Strategies.Pacing and clinical electrophysiology : PACE · 2026
- Intraprocedural left atrial appendage thrombus formation during percutaneous left atrial appendage closure: A case report.Journal of cardiology cases · 2026
- Percutaneous Closure of a Left Atrial Pseudoaneurysm After Left Atrial Appendage Closure.JACC. Case reports · 2026
- Elongated Channels Between Surgically Excluded LAA and LA: Detected by CTA But Missed by TEE.JACC. Case reports · 2026
- Percutaneous Left Atrial Appendage Closure Using a PFO Occluder After an Incomplete Surgical Ligation.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Retrograde transaortic percutaneous retrieval of a left-ventricularly embolized LAmbre occluder followed by same-session redo left atrial appendage closure: a case report.European heart journal. Case reports · 2026