Giant Aneurysm of a Classic Blalock-Taussig Shunt in Adult Tetralogy of Fallot.
Solmaz Borjian, Ali Hosseinsabet, Sahar Aslfallah, Homa Ghaderian, Nasim Torabi, Farid Maleki, Arezoo Hajiali
Department of Echocardiography, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran. · Department of Radiology, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Key points
From the paper's conclusion- Classic BT shunts may develop life-threatening aneurysmal degeneration decades after palliation, emphasizing lifelong surveillance and timely definitive management.
Abstract
BACKGROUND: Giant aneurysmal degeneration of a classic Blalock-Taussig (BT) shunt is a rare, life-threatening late complication of tetralogy of Fallot (TOF) palliation. CASE: A 47-year-old woman with unrepaired TOF palliated in childhood presented with exertional dyspnea and a right thoracic mass. Echocardiography revealed severe right ventricular outflow tract obstruction, a large ventricular septal defect, and a pulsatile extracardiac structure. Computed tomography and cardiac magnetic resonance imaging confirmed a giant (72 × 66 mm) true aneurysm of a right BT shunt. She underwent successful aneurysm excision, ventricular septal defect closure, right ventricular outflow tract reconstruction, and pulmonary valve replacement. DISCUSSION: This case demonstrates a rare late complication of a classic BT shunt decades after TOF palliation. CONCLUSION: Classic BT shunts may develop life-threatening aneurysmal degeneration decades after palliation, emphasizing lifelong surveillance and timely definitive management. TAKE-HOME MESSAGE: Lifelong imaging surveillance and multimodality imaging are essential for detecting late vascular complications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Percutaneous device closure of a massive pseudoaneurysm of the descending aorta in a paediatric patient with Takayasu arteritis.Cardiovascular journal of Africa · 2026
- Migration of a Right Ventricular Outflow Tract Stent Causing Incomplete Cardioplegic Arrest: Stent Gone Astray!Turkish journal of anaesthesiology and reanimation · 2026
- A Rare Case of Uncorrected Tetralogy of Fallot With Right Hemitruncus in an Adult Survivor Highlighting the Role of Cardiac Computed Tomography.Cureus · 2026
- Successful Repair of Giant Aortic Aneurysm With Severe Aortic Regurgitation in Fontan Patient.JACC. Case reports · 2026
- Post-Traumatic Bronchial Artery Pseudoaneurysm: A Case Report.Case reports in radiology · 2026
- Giant ascending aortic pseudoaneurysm requiring third re-do sternotomy more than two decades after aortic root replacement in an octogenarian: a case report.Journal of surgical case reports · 2026