Transcatheter Tricuspid Valve Replacement in High-Risk Elderly Patients: Procedural Feasibility, Complexity, and Delayed Conduction Disturbances.
Lucia Trabucchi, Sergio Torralbas Fitz, Rodolfo Arce, Maria I Ardid, Abraham Abdemur, Nish Patel, Ramon Quesada
Miami Cardiac and Vascular Institute, Baptist Health South Florida, Miami, Florida, USA. · Herbert Wertheim College of Medicine, Florida International University, Miami, Florida, USA.
Key points
From the paper's conclusion- We report 2 elderly high-risk patients with torrential symptomatic TR who underwent orthotopic TTVR using transfemoral venous access.
Abstract
BACKGROUND: Severe tricuspid regurgitation (TR) is associated with substantial morbidity and mortality and remains undertreated in elderly patients with prohibitive surgical risk. Transcatheter tricuspid valve replacement (TTVR) has emerged as a therapeutic option for anatomies unsuitable for transcatheter edge-to-edge repair. CASE SUMMARY: We report 2 elderly high-risk patients with torrential symptomatic TR who underwent orthotopic TTVR using transfemoral venous access. The first patient, a 94-year-old woman with prior mitral annuloplasty and a transvalvular pacemaker lead, underwent successful TTVR with complete elimination of TR and rapid symptomatic improvement. The second patient, an 84-year-old man with severe leaflet tethering and complex anatomy, underwent successful valve implantation but subsequently developed delayed complete atrioventricular block requiring leadless pacemaker implantation. DISCUSSION: These cases demonstrate the feasibility of TTVR in elderly patients with complex anatomy and highlight delayed conduction disturbances as a clinically important complication requiring extended rhythm surveillance. TAKE-HOME MESSAGES: TTVR is feasible and effective in selected elderly high-risk patients with severe TR and challenging anatomy. Delayed conduction abnormalities may occur several days after implantation and warrant structured rhythm monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Leadless Pacing for Delayed Heart Block After Transcatheter Tricupid Valve Replacement.JACC. Case reports · 2026
- Device-lead abnormalities and function after transcatheter tricuspid valve replacementEP Europace · 2025
- Safety and Feasibility of Left Bundle Branch Area Pacing Following Transcatheter Tricuspid Valve ReplacementJACC Case Reports · 2026
- Concomitant Transcatheter Aortic and Tricuspid Valve Replacement.JACC. Case reports · 2026
- Clinical, echocardiographic outcomes and complications after transcatheter tricuspid valve replacement (TTVR): a systematic review and meta-analysisEuropean Heart Journal · 2026
- Post-repair transcatheter tricuspid valve replacement for severe tricuspid regurgitationEuropean Heart Journal · 2026