JACC. Advances

Seroreactivity and Heparin Exposure in Anti-Gal IgE Sensitized Patients Following Bioprosthetic Aortic Valve Replacement.

John A Kucera, Joseph R Nellis, Seth Em Wolf, Berk Aykut, Lindsey M Reynolds, Hiba Ghandour, Michael Mensah-Mamfo, John Kyle Cook,

Congenital Heart Surgery Research and Training Laboratory, Duke University, Durham, North Carolina, USA. · Congenital Heart Surgery Research and Training Laboratory, Duke University, Durham, North Carolina, USA; Duke Department of Surgery, Duke University, Durham, North Carolina, USA.

Observational · n=270

Key points

From the paper's conclusion
  • The role of anti-gal IgE in long-term outcomes following bioprosthetic aortic valve replacement remains unclear. In addition, heparin use does appear to be safe perioperatively in this population in the absence of symptomatic alpha gal syndrome. These data suggest there is no statistically significant IgE-mediated response to alpha gal perioperatively following bioprosthetic aortic valve replacement.

Abstract

BACKGROUND: Patients may demonstrate asymptomatic seropositivity to galactose-α-1,3-galactose (alpha gal). Bioprosthetic valves contain significant alpha gal, and heparin may contain alpha gal. OBJECTIVES: This manuscript seeks to characterize perioperative anti-gal immunoglobulin E (IgE) responses in patients undergoing surgical and transcatheter bioprosthetic aortic valve replacement. It will also evaluate heparin exposure in this population undergoing bioprosthetic aortic valve replacement. METHODS: This is a single-institution prospective cohort study. Anti-gal IgE levels were assessed preoperatively and at postoperative days 1 and 3 for transcatheter and surgical aortic valve recipients, respectively. Statistical analysis was completed using Wilcoxon's signed rank test. RESULTS: A total of 270 patients underwent preoperative testing for anti-gal and total IgE. Following an Institutional Review Board amendment, an additional postoperative sample was collected from 52 patients, of which 17 were seropositive. This equated to a prevalence of 32.7% (17/52). No patients demonstrated anaphylaxis, urticaria, or other symptoms indicative of an IgE-mediated response perioperatively. The median anti-gal IgE level preoperatively was 0.31 IU/mL (interquartile range [IQR]: 2.1 IU/mL), and the overall IgE level was 39.7 IU/mL (IQR: 153.8 IU/mL). Postoperatively, the median anti-gal IgE was 0.37 IU/mL (IQR: 2.1 IU/mL) (P = 0.22), and the median overall IgE was 56.1 IU/mL (IQR: 151.6 IU/mL) (P = 0.09). CONCLUSIONS: The role of anti-gal IgE in long-term outcomes following bioprosthetic aortic valve replacement remains unclear. In addition, heparin use does appear to be safe perioperatively in this population in the absence of symptomatic alpha gal syndrome. These data suggest there is no statistically significant IgE-mediated response to alpha gal perioperatively following bioprosthetic aortic valve replacement.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers