Injury

Exposure technology and tissue protection in anterior and anterolateral thoracic/thoracolumbar fracture surgery: An international surgeon survey of retractor performance, mitigation strategies, and design priorities.

Kai-Uwe Lewandrowski, Emmanouil Liodakis, Tobias Fritz, Benedikt Burkhardt, Joachim Oertel, Kai Sprengel, Paul Park, Rossano Kepler Alvim Fiorelli,

Division Personalized Pain Research and Education, Center for Advanced Spine Care of Southern Arizona, Tucson, AZ, USA; Department of Orthopaedics, Fundación., Universitaria Sanitas, Bogotá D.C, Colombia; Department of Orthopedics, Hospital Universitário Gaffree Guinle, Universidade Federal do Estado do Rio de Janeiro, Rio de Janeiro, Brazil; Department of Orthopedic Surgery, University of Arizona Tucson Campus, Tucson, AZ, USA; Centre for Musculoskeletal Surgery (CMSC), Charitéplatz 1, Berlin 10117, Germany. Electronic address: business@tucsonspine.com. · Klinik für Unfall-, Hand, und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Homburg/Saar, Germany.

Key points

From the paper's conclusion
  • Surgeons conceptualized safe exposure as a coupled mechanical, visual, and tissue-loading problem. Future retractor systems should be evaluated at depth for stability, pressure distribution, blade geometry, illumination, imaging compatibility, and workflow using objective bench and cadaveric metrics.

Abstract

BACKGROUND: Anterior and anterolateral thoracic/thoracolumbar fracture surgery can provide direct vertebral-body and ventral canal access but requires controlled exposure through deep, anatomy-constrained corridors. We evaluated surgeon-reported retractor performance, tissue-protection behaviors, and device-design priorities. METHODS: An international web-based survey was completed by 82 surgeons from 22 countries. Detailed analyses were restricted to 39 surgeons who reported personal anterior/anterolateral T4-L2 fracture surgery within 5 years. Likert items, multi-select mitigation strategies, and 26 free-text design responses were summarized descriptively; Rasch hierarchy, specialty differential item functioning (DIF), and MADQ3 residual correlations were exploratory response-structure analyses. RESULTS: Standard rib spreaders, table-mounted ring retractors, and expandable lateral retractors were each used by 17/39 surgeons (43.6%). Prominent signals were large body habitus increasing difficulty and pressure (28/33, 84.8%), adjunct visualization (28/35, 80.0%), T11-L2 working distance (27/34, 79.4%), stability/minimal creep (26/37, 70.3%), and blade geometry (21/31, 67.7%). Common protective strategies were avoiding the inferior-rib neurovascular bundle (23/39, 59.0%), periodic partial release (20/39, 51.3%), and limiting blade opening according to imaging or chest-wall size (15/39, 38.5%). Overall soft-tissue risk (7/36, 19.4%) and reported complication frequency (1/33, 3.0%) had lower upper-category endorsement. Design responses prioritized blade geometry/pressure distribution (13/26, 50.0%), integrated illumination (12/26, 46.2%), and imaging/optical integration (11/26, 42.3%). No DIF signal survived false-discovery-rate correction. CONCLUSIONS: Surgeons conceptualized safe exposure as a coupled mechanical, visual, and tissue-loading problem. Future retractor systems should be evaluated at depth for stability, pressure distribution, blade geometry, illumination, imaging compatibility, and workflow using objective bench and cadaveric metrics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers