Prospective Phase II Study of Stereotactic MR-Guided Adaptive Radiotherapy (SMART) for Primary Renal Tumors: Organ-at-Risk-Constrained Dose Modulation.
Takaya Yamamoto, Shohei Tanaka, Rei Umezawa, Noriyoshi Takahashi, Yu Suzuki, Keita Kishida, So Omata, Kazuya Takeda,
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan. Electronic address: takaya.yamamoto.c3@tohoku.ac.jp. · Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Key points
From the paper's conclusion- SMART was feasible, with encouraging short-term local control and no treatment-related serious adverse events excluding nephrotoxicity. Daily OAR-constrained dose modulation may allow treatment of OAR-adjacent tumors previously considered unsuitable for stereotactic body radiotherapy. Longer follow-up and multicenter studies are warranted.
Abstract
PURPOSE: Primary renal tumors vary in their proximity to organs at risk (OARs), particularly the gastrointestinal tract. This prospective study evaluated the feasibility, safety, and local control of stereotactic MR-guided adaptive radiotherapy (SMART) with prospectively permitted OAR-constrained dose de-escalation. MATERIALS AND METHODS: This single-institution phase II trial enrolled patients with a T1N0M0 primary renal tumor ≤5 cm who were ineligible for or declined surgery or ablation. Baseline renal function was not an exclusion criterion. SMART was delivered on an MR-linac (Elekta Unity) at 42 Gy in 3 fractions, reduced in 3 Gy steps (minimum, 30 Gy) if OAR constraints could not be met. The co-primary endpoints were the 1-year local control rate and the rate of serious adverse events (grade ≥3, excluding nephrotoxicity). RESULTS: Twenty-five patients were enrolled between May 2022 and December 2024 (median age, 79 years; median tumor diameter, 22 mm); no spacer was used. Prescribed doses were 42 Gy in 22 patients, 36 Gy in 1, and 30 Gy in 2; all patients completed 3 fractions. With a median follow-up of 22.1 months, no local or distant recurrence was observed; one patient died of an unrelated cause. The 1-year local control rate was 100% (95% CI, 86.3%-100%). One serious adverse event occurred (4%; 95% CI, 0.1%-20.4%; grade 3 myocardial infarction, judged unrelated to SMART). In 22 patients evaluable for renal function, the median change in estimated glomerular filtration rate (eGFR) was -7.5 mL/min/1.73 m² (interquartile range, -10.0 to -4.2); one additional patient with baseline eGFR <15 mL/min/1.73 m² initiated dialysis at 4 months. CONCLUSIONS: SMART was feasible, with encouraging short-term local control and no treatment-related serious adverse events excluding nephrotoxicity. Daily OAR-constrained dose modulation may allow treatment of OAR-adjacent tumors previously considered unsuitable for stereotactic body radiotherapy. Longer follow-up and multicenter studies are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stereotactic MRI-guided adaptive radiation therapy (SMART) for locally advanced pancreatic cancer: A prospective single-center cohort study.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Phase II Trial of Stereotactic Body Radiotherapy to Oligoprogressive Lesions from Oligometastatic Renal Cell Carcinoma on First-line Systemic Therapy.International journal of radiation oncology, biology, physics · 2026
- Case Report: MR-guided adaptive stereotactic body radiotherapy for splenic metastases: a case series of technical feasibility and early clinical outcomes.Frontiers in oncology · 2026
- Selective Arterial Embolization for Renal Angiomyolipoma: A Giant Versus Non-Giant Lesion Subgroup Comparison.Life (Basel, Switzerland) · 2026
- Safely Navigating the MR-Linac: A New Risk Framework for Prostate SBRT Patients with Cardiac Devices.Practical radiation oncology · 2026
- LINAC-based online adaptive stereotactic ablative radiotherapy for kidney tumors: In silico analysis.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026