International journal of radiation oncology, biology, physics

Efficacy and Safety of Adjuvant Single-Fraction Radiotherapy for Excised Keloids: A Prospective Randomized Controlled Trial.

Tyng-Luen Roan, Dun-Hao Chang, Deng-Yu Kuo, Pei-Wei Shueng, Yu-Fang Lin, Hui-Ju Tien, Chen-Hsi Hsieh

Division of Plastic and Aesthetic Surgery, Department of Surgery, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan. Electronic address: troan0318@gmail.com. · Division of Plastic and Aesthetic Surgery, Department of Surgery, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan; School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan. Electronic address: jchang50002000@gmail.com.

Randomised

Key points

From the paper's conclusion
  • A 13 Gy single-fraction postoperative regimen provided superior local control and cosmetic outcomes compared with 9 Gy, particularly at high-tension anatomic sites. These findings support a risk-stratified, tension-based dosing strategy, wherein dose de-escalation may be considered at low-tension sites without compromising local control.

Abstract

PURPOSE: While fractionated postoperative radiotherapy regimens for keloids are well established, the optimal dose for single-fraction delivery remains to be definitively defined. This prospective, randomized trial characterized the dose-response relationship of single-fraction radiotherapy and evaluated the impact of local tissue tension on treatment outcomes. METHODS AND MATERIALS: Eighty-eight patients with surgically excised keloids were randomized to receive a single fraction of electron beam radiotherapy at 9 Gy (n = 30), 11 Gy (n = 29), and 13 Gy (n = 29) within 24 hours of surgery. The primary endpoint was 12-month local control. Secondary endpoints included objective scar assessment using the modified Vancouver Scar Scale (mVSS) and patient-reported quality of life via Skindex-16. RESULTS: At 12 months, recurrence rates were 23.3%, 17.2%, and 6.9% for the 9, 11, and 13 Gy groups, respectively. In multivariable logistic regression, the 9 Gy dose was an independent predictor of recurrence relative to 13 Gy (OR, 5.7; 95% CI, 1.0-32.3; P = .046). Longitudinal analysis using generalized estimating equations demonstrated superior objective scar outcomes in the 13 Gy group compared with 9 Gy (P < .001) and 11 Gy (P < .001). Receiver operating characteristic analysis identified an mVSS score ≥ 7 as a highly accurate predictor of recurrence (AUC = 0.93). CONCLUSIONS: A 13 Gy single-fraction postoperative regimen provided superior local control and cosmetic outcomes compared with 9 Gy, particularly at high-tension anatomic sites. These findings support a risk-stratified, tension-based dosing strategy, wherein dose de-escalation may be considered at low-tension sites without compromising local control.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers