International journal of radiation oncology, biology, physics

Dose-time-response relationships between radiation dose to the circulating blood and temporal changes in peripheral blood biomarkers during chemoradiation of non-small cell lung cancer.

Mathieu Gaudreault, Philippa Johnstone, Anson Chen, Katrina Woodford, Kenton Thompson, Nicholas Hardcastle, Vanessa Panettieri, Michael MacManus

Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia. Electronic address: mathieu.gaudreault@petermac.org. · Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; Sir Peter MacCallum Department of Oncology, the University of Melbourne, Victoria 3000, Australia.

Key points

From the paper's conclusion
  • Hematological toxicities were frequent in NSCLC patients treated with VMAT chemoradiotherapy. Radiation exposure was associated with changes in circulating lymphocyte counts and hemoglobin, supporting prospective investigation into reducing circulating blood dose during chemoradiation to mitigate hematological toxicity.

Abstract

PURPOSE: Chemoradiotherapy commonly causes radiation-induced lymphopenia, neutropenia, and anemia, as measured by reductions in absolute lymphocyte count (ALC), absolute neutrophil count (ANC), and hemoglobin level (Hb). We aimed to quantify these hematological toxicities and characterize dose-time-response relationships between temporal changes in peripheral blood biomarkers and radiation exposure to the circulating blood during volumetric modulated arc therapy (VMAT) definitive chemoradiotherapy for non-small cell lung cancer (NSCLC). METHODS AND MATERIALS: Blood biomarker measurements were collected from 93 NSCLC patients, treated between 2018 and 2024, at pre-, during-, and post-treatment time points. Radiotherapy prescription doses were 60 Gy in 30 fractions, 55 Gy in 20 fractions, or 50 Gy in 25 fractions with concurrent platinum-based chemotherapy. Organs at risks were delineated by the TotalSegmentator software. The blood dose-volume histogram was estimated through simulations of blood dynamics using the HEDOS software and VMAT dose accumulation was calculated with the BeamSplitter algorithm. Dose-time-response relationships were modelled by linear and exponentially decaying curves, from which rates of change were extracted and goodness of fit quantified using the R2- value. RESULTS: Baseline blood biomarker values (median ± interquartile range) were (1.8±0.9) × 109/L for ALC, (5.6±3.0) × 109/L for ANC, and 132±19 g/L for Hb. Prior to treatment, 0%, 0%, and 30% of patients exhibited lymphopenia, neutropenia, and anemia, respectively. During treatment, these proportions increased to 71%, 19%, and 77%. Dose-response analysis revealed rates of change at low doses of radiation: -69%/Gy (ALC), -83%/Gy (ANC), and -3%/Gy (Hb), with model fits showing R² values between 0.78 and 0.96. CONCLUSIONS: Hematological toxicities were frequent in NSCLC patients treated with VMAT chemoradiotherapy. Radiation exposure was associated with changes in circulating lymphocyte counts and hemoglobin, supporting prospective investigation into reducing circulating blood dose during chemoradiation to mitigate hematological toxicity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers