◆ International journal of radiation oncology, biology, physics2026-08-31

State-Aware Contactless Respiratory Volume Monitoring for Breath-Hold-Guided Radiotherapy.

Jiahao Yang, Zixin Li, Sai Zhang, Hao Wang, Heng Zhang, Yutao Zhang, Xiaoshuang Tu, Xinye Ni

一句话结论 · In one sentence

The proposed contactless framework enables stable tidal-volume estimation and real-time visual feedback during DIBH while minimizing patient encumbrance, supporting low-burden respiratory monitoring for radiotherapy workflows.

原始摘要(英文原文)· Original abstract
PURPOSE: Respiratory motion increases setup uncertainty in thoracic and abdominal tumor radiotherapy and elevates dose exposure to organs at risk (OARs), such as the heart and lungs. Deep inspiration breath-hold (DIBH) can reduce OARs dose, but clinical deployment requires accurate, real-time, low-burden monitoring of breath-hold stability and tidal volume. This study proposes a contactless tidal volume estimation system for DIBH-guided radiotherapy. METHODS: A depth camera captured three-dimensional thoracoabdominal surface motion to construct a surface-based volumetric surrogate. A state-aware, surrogate-guided time-series regression model incorporating dynamic state gating, steady-state anchor modeling, adaptive baseline correction, and subject-specific calibration was developed for tidal volume estimation. In this prospective model-development and pilot internal-validation study, synchronized depth-camera data and tidal volume signals from an Active Breathing Coordinator (ABC) system were collected from 22 volunteers. ABC-derived tidal volume served as the reference signal, and performance was evaluated using subject-independent leave-one-subject-out cross-validation. Real-time respiratory feedback was provided through a head-mounted visualization interface. RESULTS: Predicted tidal volume strongly correlated with the ABC reference signal (pooled r=0.968; subject-level Fisher z-transformed mean r=0.966, 95% CI: 0.954-0.975, p<0.001), with an overall MAE of 0.098 L. Phase-specific MAE/MAPE were 0.1059 L/17.27% during breath hold and 0.0967 L/16.68% during normal breathing. GPU-side algorithmic latency was 12.55 ms per frame. CONCLUSION: The proposed contactless framework enables stable tidal-volume estimation and real-time visual feedback during DIBH while minimizing patient encumbrance, supporting low-burden respiratory monitoring for radiotherapy workflows.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

State-Aware Contactless Respiratory Volume Monitoring for Breath-Hold-Guided Radiotherapy. — 科研速览 Science Skim