International journal of pharmaceutics

Translational feasibility of acoustic monitoring for cumulative lung-delivered dose during routine dry powder inhaler use.

Mou-Wei Chang, Chun-Hao Fan, Chun-Wei Chiu, Ting-Yu Hu, Yu-Te Liao, Wei-Ren Ke, Wen-Jui Wu

Department of Electronics and Electrical Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan. · School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan.

Key points

From the paper's conclusion
  • We report a prospective real-world evaluation of an acoustic sensing system that estimates cumulative pulmonary exposure during routine dry powder inhaler (DPI) use without modifying the inhaler.

Abstract

Conventional inhaler monitoring based on actuation counts does not capture the inhalation profiles that determine pulmonary drug deposition, and existing in vitro metrics are not directly translatable to real-world pulmonary exposure. We report a prospective real-world evaluation of an acoustic sensing system that estimates cumulative pulmonary exposure during routine dry powder inhaler (DPI) use without modifying the inhaler. The system combines noncontact acoustic sensing, acoustic-to-flow reconstruction, and an in-vitro-derived deposition response surface model to estimate lung deposition fraction, accumulated over predefined time windows as the estimated lung-delivered dose (ELDD), an in vitro-derived surrogate of cumulative pulmonary exposure. We evaluated the system in a 24-week prospective observational study of 103 adults with asthma using Turbuhaler to evaluate system feasibility and examine associations between ELDD and subsequent changes in Asthma Control Test (ACT). The system captured 17,717 valid inhalation profiles from the cohort. The mean lung deposition fraction was 32.8 ± 10.4%, and the mean 4-week ELDD was 2,382 μg. In the association analysis (48 participants, 166 exposure-outcome intervals), higher ELDD was associated with lower odds of subsequent exploratory directional ACT decline, although the association did not reach statistical significance (p = 0.055). In a sensitivity analysis extending the exposure window to 8 weeks, the group difference reached significance (p = 0.023), consistent with the known delayed anti-inflammatory effects of inhaled corticosteroids. Continuous acoustic monitoring of DPI use in routine outpatient care was feasible over a 24-week period without inhaler modification or supervised testing. Preliminary association analyses suggested that estimated cumulative pulmonary exposure may relate to subsequent asthma control outcomes, warranting further investigation in larger confirmatory studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Translational feasibility of acoustic monitoring for cumulative lung-delivered dose during routine dry powder inhaler use — Science Skim