Real-time monitoring of aluminum phosphate sedimentation and resuspension using electrical resistance tomography.
Riccardo Pellicari, Federico Alberini, Alessandro Paglianti, Stephen L J Luckham, Carlo Pergola, Andrea Albano
Department of Industrial Chemistry 'Toso Montanari', University of Bologna, Via Piero Gobetti 85, 40129 Bologna, Italy; Global Drug Product Development, DDS - R&D, GSK, Siena 53100, Italy. Electronic address: riccardo.pellicari2@unibo.it. · Department of Industrial Chemistry 'Toso Montanari', University of Bologna, Via Piero Gobetti 85, 40129 Bologna, Italy. Electronic address: federico.alberini@unibo.it.
Key points
From the paper's conclusion- This work investigates Electrical Resistance Tomography (ERT) as a non-invasive Process Analytical Technology for real-time monitoring of AP sedimentation and resuspension in a stirred tank at formulation-relevant concentrations below 1% v/v.
Abstract
Aluminum phosphate (AP) is widely used as a vaccine adjuvant, but its tendency to sediment and form consolidated layers can affect suspension homogeneity during manufacturing, transfer, storage, and filling operations. This work investigates Electrical Resistance Tomography (ERT) as a non-invasive Process Analytical Technology for real-time monitoring of AP sedimentation and resuspension in a stirred tank at formulation-relevant concentrations below 1% v/v. A custom-designed bottom linear ERT probe was used to detect conductivity changes associated with solids accumulation near the vessel bottom and clarification of the bulk liquid phase. Rheological characterization showed that AP suspensions become increasingly structured and shear-sensitive with increasing concentration, supporting the interpretation of sedimentation as a concentration-dependent, hindered-settling process. ERT measurements enabled visualization of sediment formation, identification of different settling regimes consistent with Kynch theory, and extraction of apparent settling velocities. Complete settling times decreased markedly with dilution, from approximately 180 min at 1 mg/mL to 55 min at 0.5 mg/mL and 10 min at 0.25 mg/mL. The ERT-derived sedimentation profiles showed good agreement with optical measurements and literature data obtained under comparable conditions. These results demonstrate that ERT can provide process-relevant, spatially resolved information on suspension homogeneity, sediment growth, and resuspension dynamics in aluminum-adjuvanted vaccine systems. The approach may support formulation development, agitation strategy definition, and real-time process control for vaccine manufacturing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aqueous channel topology governs resuspension in aluminum phosphate colloidal formulations.Journal of pharmaceutical sciences · 2026
- Diagnosis for graphite-based anode slurries via in-line electrochemical impedance spectroscopy under pipe flowKorea-Australia Rheology Journal · 2026
- Sedimentation Potential of Charged Spherical Colloidal Particles in an Uncharged Polymer Gel Medium: An Onsager Reciprocal Relation Approach.Electrophoresis · 2026
- Stirring the Pot: Surprising Observation of Polytetrafluoroethylene (PTFE)-Containing Particles When Stir-stressing Biologic Formulations with PTFE-coated Stir Bars.Journal of pharmaceutical sciences · 2026
- Intrinsic Backflow in Heterogeneous Aquifer During Electrokinetic Remediation: A Challenge in Field‐Scale ApplicationGeophysical Research Letters · 2026
- Evaporation-induced colloidal diffusiophoresis in electrolyte solutionsarXiv · 2026