CoolStick vs. ethyl chloride spray for sensory block testing to light touch and cold for caesarean delivery under neuraxial anaesthesia: a paired method-comparison study with randomised test order.
Matthew Wikner, Simon Apps, Bhavesh Gohil, Natasha Kennedy, Ilaria Roncagliolo, Hannah Bykar, Sriveena Naganathar, Akshaykumar Patel,
Royal London Hospital, Barts Health NHS Trust, London, United Kingdom. Electronic address: matthew.wikner@nhs.net. · Royal London Hospital, Barts Health NHS Trust, London, United Kingdom.
Key points
From the paper's conclusion- We recruited 64 women between April and November 2025. The median [interquartile range] age was 34 (30-37) years. The intraclass correlation coefficient for light touch was 0.87 (95% CI 0.78-0.92, P < 0.001), and for cold was 0.89 (95% CI 0.83-0.93, P < 0.001). Median bias for light touch was 0 dermatomes (95% limits of agreement -1 to 4, p = 0.002) and for cold was 0 dermatomes (-2 to 1, P = 0.06). No patient reported pain within 60 min.
Abstract
BACKGROUND: Light touch sensation is recommended when testing neuraxial anaesthesia for caesarean delivery. This is commonly assessed using ethyl chloride spray. CoolStick is a more environmentally sustainable device that has not been compared to conventional methods. METHODS: This was a multicentre prospective paired method-comparison study with randomised test order involving participants undergoing planned caesarean delivery with spinal or combined spinal-epidural anaesthesia. Participants were tested with both CoolStick and ethyl chloride 10 min post-spinal, with the initial method chosen at random. The primary endpoint was dermatomal level to light touch, and the secondary endpoint was dermatomal level to cold. We also assessed pain within 60 min of spinal injection. Agreement between testing methods was assessed using the intraclass correlation coefficient, with bias and limits of agreement assessed using Bland-Altman plots and the Wilcoxon signed rank test. RESULTS: We recruited 64 women between April and November 2025. The median [interquartile range] age was 34 (30-37) years. The intraclass correlation coefficient for light touch was 0.87 (95% CI 0.78-0.92, P < 0.001), and for cold was 0.89 (95% CI 0.83-0.93, P < 0.001). Median bias for light touch was 0 dermatomes (95% limits of agreement -1 to 4, p = 0.002) and for cold was 0 dermatomes (-2 to 1, P = 0.06). No patient reported pain within 60 min. DISCUSSION: We found high overall agreement between devices for both light touch and cold testing. However, CoolStick recorded light touch levels several dermatomes lower than ethyl chloride in a small proportion of patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pain, sensory acceptability, and treatment compliance following cryotherapy and topical anesthetics in children: A randomized clinical trial.PloS one · 2026
- A nurse-delivered analgesia pathway for severe pain reduction during radial accessEuropean Heart Journal · 2026
- Comparison of lignocaine spray 10% versus normal saline spray for pain relief during intravenous cannulation in adultsAsian Journal of Medical Sciences · 2026
- A calibrated blunt-clamp refinement of the cutaneous trunk muscle reflex assay for standardized assessment of nociceptive responses and local anesthetic effects in ratsBMC Anesthesiology · 2026
- Efficacy of ethyl chloride topical anesthesia application on pain perception during intra-oral injections in children compared to benzocaine gel-a single-blind randomized controlled trial.Frontiers in dental medicine · 2026
- Comparison between cryoanalgesia, epidural anaesthesia and erector spinae plane block for postoperative analgesia after minimally-invasive anatomic lung resection: a randomized controlled trial.Updates in surgery · 2026