International Journal of Hydrogen EnergyOpen accessMechanism

TiO2/PdO-based eye-detectable fast-responding sensor to address H2 safety infrastructure: Unveiling the colour change mechanism and active sites

Ananya Mandal, Sujana Chandrappa, Dharmapura H. K. Murthy, Swati Neogi

Indian Institute of Technology Kharagpur · Manipal Academy of Higher Education

Key points

From the paper's conclusion
  • A TiO2/PdO composite chemochromic hydrogen sensor is optimized by tuning TiO2 particle size and Pd precursor concentration to achieve rapid, highly sensitive, eye-readable hydrogen detection.
  • The optimized sensor exhibits an eye-readable colour change within 4 s at 4 vol% hydrogen in nitrogen, corresponding to the lower flammability limit of hydrogen.
  • Ti–Pd ground-state interactions drive hydrogen adsorption and the optoelectronic changes responsible for the colour response.

Abstract

Deployment of hydrogen-based infrastructure is impeded by the difficulty of real-time detection of hydrogen leaks. To address this issue, a TiO 2 /PdO composite chemochromic hydrogen sensor is optimized by tuning TiO 2 particle size and Pd precursor concentration to achieve rapid, highly sensitive, eye-readable hydrogen detection. The optimized sensor exhibits an eye-readable colour change within 4 s at 4 vol% hydrogen in nitrogen, corresponding to the lower flammability limit of hydrogen, making it suitable for real-time leak detection. Through systematic investigations, correlations between hydrogen concentration, catalyst loading, magnitude of colour change, and response time are established. A maximum colour difference of ΔE = 28.86 is achieved by the optimized sensor in pure hydrogen. Spectroscopy and microscopy studies revealed that Ti–Pd ground-state interactions drive hydrogen adsorption and the optoelectronic changes responsible for the colour response, providing design guidelines for the development of rapid chemochromic hydrogen sensors.

Read the paper

Discussion · 1

Science Skim's AI key points, plus readers' public thoughts

Science SkimAI key points
Pinned
  • A TiO2/PdO composite chemochromic hydrogen sensor is optimized by tuning TiO2 particle size and Pd precursor concentration to achieve rapid, highly sensitive, eye-readable hydrogen detection.
  • The optimized sensor exhibits an eye-readable colour change within 4 s at 4 vol% hydrogen in nitrogen, corresponding to the lower flammability limit of hydrogen.
  • Ti–Pd ground-state interactions drive hydrogen adsorption and the optoelectronic changes responsible for the colour response.

Readers' thoughts

No reader thoughts yet.

Related papers