TiO2/PdO-based eye-detectable fast-responding sensor to address H2 safety infrastructure: Unveiling the colour change mechanism and active sites
Ananya Mandal, Sujana Chandrappa, Dharmapura H. K. Murthy, Swati Neogi
Indian Institute of Technology Kharagpur · Manipal Academy of Higher Education
Key points
From the paper's conclusion- A TiO2/PdO composite chemochromic hydrogen sensor is optimized by tuning TiO2 particle size and Pd precursor concentration to achieve rapid, highly sensitive, eye-readable hydrogen detection.
- The optimized sensor exhibits an eye-readable colour change within 4 s at 4 vol% hydrogen in nitrogen, corresponding to the lower flammability limit of hydrogen.
- Ti–Pd ground-state interactions drive hydrogen adsorption and the optoelectronic changes responsible for the colour response.
Abstract
Deployment of hydrogen-based infrastructure is impeded by the difficulty of real-time detection of hydrogen leaks. To address this issue, a TiO 2 /PdO composite chemochromic hydrogen sensor is optimized by tuning TiO 2 particle size and Pd precursor concentration to achieve rapid, highly sensitive, eye-readable hydrogen detection. The optimized sensor exhibits an eye-readable colour change within 4 s at 4 vol% hydrogen in nitrogen, corresponding to the lower flammability limit of hydrogen, making it suitable for real-time leak detection. Through systematic investigations, correlations between hydrogen concentration, catalyst loading, magnitude of colour change, and response time are established. A maximum colour difference of ΔE = 28.86 is achieved by the optimized sensor in pure hydrogen. Spectroscopy and microscopy studies revealed that Ti–Pd ground-state interactions drive hydrogen adsorption and the optoelectronic changes responsible for the colour response, providing design guidelines for the development of rapid chemochromic hydrogen sensors.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- A TiO2/PdO composite chemochromic hydrogen sensor is optimized by tuning TiO2 particle size and Pd precursor concentration to achieve rapid, highly sensitive, eye-readable hydrogen detection.
- The optimized sensor exhibits an eye-readable colour change within 4 s at 4 vol% hydrogen in nitrogen, corresponding to the lower flammability limit of hydrogen.
- Ti–Pd ground-state interactions drive hydrogen adsorption and the optoelectronic changes responsible for the colour response.
Readers' thoughts
No reader thoughts yet.
Related papers
- An Ambient Gasochromic Hydrogen Gas Sensor Based on a Pd/Mo Bimetallic Catalyst and Azo Dyes.ACS sensors · 2026
- Cavity-Enhanced Eye-Readable Detection of 0.1% H2 via Active Modulation of Charge-Transfer Plasmons.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Morphology-Encoded Colorimetric Hydrogen Sensing Using Embedded Reactive Pd Absorbers in Fabry-Perot Cavities.Advanced materials (Deerfield Beach, Fla.) · 2026
- Interfacial Control of Hydrogen Exchange Kinetics in Ultrathin Nanostructured PdCo Chemiresistive Sensors.ACS sensors · 2026