Feasibility and safety of a standardized low-dose thrombolytic therapy for right-sided mechanical prosthetic valve thrombosis in adult congenital heart disease.
Naoto Shingu, Tomoyasu Suenaga, Ayako Ishikita, Soshun Asakawa, Masahiko Umei, Akiko Nishizaki, Takamori Kakino, Ichiro Sakamoto,
Department of Cardiovascular Medicine, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan. · Department of Pediatrics, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Key points
From the paper's conclusion- Standardized low-dose thrombolytic therapy was safe and feasible in this case series and may provide a non-surgical treatment option for ACHD patients with right-sided mechanical valve thrombosis.
Abstract
BACKGROUND: Mechanical valve thrombosis is a serious complication in adults with congenital heart disease (ACHD). Although low-dose thrombolytic therapy has emerged as a potential alternative to surgery, evidence in ACHD patients with right-sided mechanical valve thrombosis remains limited. We evaluated the feasibility and safety of a standardized low-dose thrombolytic protocol in this population. METHODS: We retrospectively reviewed consecutive ACHD patients with right-sided mechanical valve thrombosis treated at our institution between 2022 and 2025. Diagnosis was based on fluoroscopic, echocardiographic, and computed tomography findings. All patients received a standardized low-dose alteplase regimen (25 mg over 6 h). Treatment efficacy was assessed primarily by restoration of prosthetic leaflet mobility on fluoroscopy. RESULTS: Five patients were included: four with mechanical pulmonary valves and one with a mechanical tricuspid valve. Thrombosis occurred a median of 2.3 years after valve replacement, and all patients had subtherapeutic anticoagulation (international normalized ratio <2.0) during the preceding month. At presentation, four patients were in New York Heart Association functional class II and one in class III. Following a median of 5 days of thrombolytic therapy, complete restoration of prosthetic leaflet mobility was achieved in all patients. No major bleeding or thromboembolic complications occurred. During a median follow-up of 0.7 years, no recurrent valve thrombosis was observed. CONCLUSIONS: Standardized low-dose thrombolytic therapy was safe and feasible in this case series and may provide a non-surgical treatment option for ACHD patients with right-sided mechanical valve thrombosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful Medical Management of Obstructive Mechanical Mitral Valve Thrombosis Using Low-Dose, Ultraslow Infusion Thrombolytic Therapy: A Case Report.Case reports in cardiology · 2026
- Tenecteplase vs Alteplase in Mechanical Prosthetic Heart Valve Thrombosis: The TENET Randomized Clinical Trial.JAMA cardiology · 2026
- Acute Mechanical Mitral Valve Thrombosis Treated by Endovascular Recombinant Tissue Plasminogen Activator in a 2-Year-Old.JACC. Case reports · 2026
- Slow/ultraslow low-dose thrombolytic therapy for mechanical prosthetic valve thrombosis: a multicenter patient-level pooled analysisEuropean Heart Journal · 2026
- Low-Dose Tenecteplase for Acute Ischemic Stroke Treatment in Aging Patients DATE-AGING Trial: Rationale and DesignmedRxiv · 2026
- Outcomes of thrombolytic therapy in prosthetic valve thrombosis; a single centre study.Pakistan journal of medical sciences · 2026