International journal of cardiology

Head-to-head comparison of multimodal models incorporating clinical, imaging, and epicardial adipose tissue radiomics for predicting the 3-year MACEs in patients with stable angina.

Rui Guo, Pengpeng Zuo, Hao Zhou, Ning Chen, Dan Wu, Jian Lei, Zhipeng Huang, Yanqiu Pang,

Department of Radiology, Xinjiang Production and Construction Corps Hospital, No. 232 Qingnian Road, Tianshan District, Xijiang Uygur Autonomous Region, Urumqi 830000, China. · Department of Radiology, Xinjiang Production and Construction Corps Hospital, No. 232 Qingnian Road, Tianshan District, Xijiang Uygur Autonomous Region, Urumqi 830000, China. Electronic address: missingshz@163.com.

Observational · n=153

Key points

From the paper's conclusion
  • A routine clinical-imaging model provided excellent 3-year MACE prediction (test AUC 0.897), with no incremental benefit from EAT radiomics. The clinical-imaging model is simple, low-cost, and ready for integration into routine CCTA-based risk stratification.

Abstract

BACKGROUND: In patients with stable angina pectoris (SAP), the prognostic value of a multimodal model combining conventional coronary computed tomography angiography (CCTA) parameters and epicardial adipose tissue (EAT) radiomics for predicting major adverse cardiovascular events (MACEs) has not been systematically compared. METHODS: We retrospectively enrolled 153 patients with SAP who underwent CCTA. The cohort was randomly split into training (n = 107) and test (n = 46) sets. The composite MACE endpoints included cardiac death, myocardial infarction, hospitalization for acute heart failure, and revascularization (none occurred). Clinical and imaging features were selected using univariate/multivariate logistic regression models, and EAT radiomic features were reduced via Least Absolute Shrinkage and Selection Operator (LASSO) regression. Logistic regression with L2 regularization was used to construct five models: clinical, imaging, radiomics, clinical-imaging, and full (clinical-imaging-radiomics) models. Performance was assessed by calculating the area under the curve (AUC), calibration, and decision curve analysis. RESULTS: The clinical-imaging model achieved a test AUC of 0.897 (95% CI 0.800-0.995), outperforming the clinical (0.812, 0.677-0.948) and radiomics-only (0.836, 0.722-0.950) models. The full model had a test AUC of 0.895 (0.798-0.993), not significantly different (P = 0.265). All models showed good calibration (Hosmer-Lemeshow, all P > 0.05). Decision curve analysis showed net benefit across risk thresholds 0.1-0.8, with the clinical-imaging model being the most practical. CONCLUSIONS: A routine clinical-imaging model provided excellent 3-year MACE prediction (test AUC 0.897), with no incremental benefit from EAT radiomics. The clinical-imaging model is simple, low-cost, and ready for integration into routine CCTA-based risk stratification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers