Early outcomes of the Octapro balloon-expandable transcatheter heart valve in an unrestricted cohort of patients with aortic valve stenosis: the MyPro registry.
Alfonso Ielasi, Elisabetta Moscarella, Gregor Verček, Christian Frerker, Luca Testa, Alexander Ijsselmuiden, Francesco Maisano, Gioel Gabrio Secco,
U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy. Electronic address: alfonso.ielasi@gmail.com. · Department of Translational Medical Sciences, University of Campania "Luigi Vanvitelli", Naples, Italy.
Key points
From the paper's conclusion- In this real-world registry, the Octapro THV demonstrated high procedural success, favourable early clinical outcomes, and excellent haemodynamic performance. Implantation depth and baseline RBBB were independent predictors of PPI, supporting optimization of implantation technique to mitigate conduction disturbances.
Abstract
BACKGROUND: Data on early outcomes of the novel balloon-expandable (BE) Octapro transcatheter heart valve (THV) in real-world practice are limited. We sought to assess procedural safety and early outcomes of the Octapro in patients with severe native aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Between November 2024 and October 2025, consecutive patients with severe AS undergoing TAVI with Octapro in European and Indian centres were enrolled. Primary endpoints were VARC-3 technical success, device success, and early safety at 30-day. RESULTS: A total of 303 patients were included (age 78.9 ± 7.4 years; bicuspid 13%). VARC-3 technical success was 97%, peri-procedural mortality 0.3% while no procedural stroke or myocardial infarction were reported. In-hospital guidelines-indicated permanent pacemaker implantation (PPI) rate was 13.5%. At discharge mean gradient was 8.4 ± 4.5 mmHg, effective orifice area 1.8 ± 0.3 cm2, while moderate-to-severe paravalvular leak was reported in 3.3% of the patients. At 30-day, device success was 92.4% and early safety 80%. All-cause mortality was 2.6%, stroke 0.3%, and guidelines-indicated PPI 14.2%. Mean gradient remained low (9 ± 4 mmHg). Implantation depth and baseline right bundle branch block (RBBB) were independent predictors of PPI. ROC analysis identified an implantation depth threshold of 4.75 mm associated with increased PPI risk. CONCLUSIONS: In this real-world registry, the Octapro THV demonstrated high procedural success, favourable early clinical outcomes, and excellent haemodynamic performance. Implantation depth and baseline RBBB were independent predictors of PPI, supporting optimization of implantation technique to mitigate conduction disturbances.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimized Balloon-Expandable Transcatheter Aortic Valve Implantation and Clinical Outcomes.JACC. Advances · 2026
- Clinical Outcomes of the Allegra Transcatheter System in Bioprosthetic Aortic Valve Failure: A Multicentre Valve-in-Valve Registry.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.Journal of cardiovascular medicine (Hagerstown, Md.) · 2026
- Feasibility and Procedural Considerations of Balloon-Expandable TAVR in Patients With Prior Endovascular Aortic Stent Grafts.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Comparative outcomes of balloon-expandable versus self-expanding transcatheter aortic valves: insights from a large-scale German registry.BMC cardiovascular disorders · 2026
- Long-term outcomes and durability of balloon-expandable TAVI in small and large annuliEuroIntervention · 2025