International journal of biological macromolecules

Development of a novel blocking ELISA based on a monoclonal antibody targeting conserved epitope on ApxIVA for evaluating Actinobacillus pleuropneumoniae.

Min Yuan, Qi Wu, Shuang Jiang, Chunchun Xu, Shuhui Wu, Hechao Zhu, Lei Ma, Huiqin Jia,

National Key Laboratory of Agricultural Microbiology, Hubei Hongshan Laboratory, College of Veterinary Medicine, Huazhong Agricultural University, Wuhan, Hubei, 430070, China; Key Laboratory of Preventive Veterinary Medicine in Hubei Province, The Cooperative Innovation Center for Sustainable Pig Production, Wuhan, Hubei, 430070, China. · College of Life Sciences, Chongqing Normal University, Chongqing, 401331, China.

Key points

From the paper's conclusion
  • A blocking ELISA (bELISA) antibody detection method was established based on this protein and mAb-1D5.

Abstract

Porcine contagious pleuropneumonia (PCP) caused by Actinobacillus pleuropneumoniae (APP) severely threatens the global swine industry. Reliable differential diagnosis is crucial for disease control and APP eradication. The ApxIV toxin, a species-specific virulence factor secreted by all APP serovars and expressed exclusively in infected animals, serves as a key target for differentiating naturally infected pigs from vaccinated pigs. In this study, a monoclonal antibody (mAb) 1D5 against ApxIVA was generated using hybridoma technology. Through protein truncation, prediction of antigen-antibody complex structures, and point mutation validation, TYR436 was identified as a residue critical for mAb-1D5 recognition. This residue was conserved in all 169 ApxIVA sequences included in the analysis. A soluble truncated ApxIVA protein, rApxIVA T2 (348573 aa), containing TYR436, was constructed and successfully expressed in a prokaryotic system and purified. A blocking ELISA (bELISA) antibody detection method was established based on this protein and mAb-1D5. A cutoff value of 42.86% was established using a development panel of 206 sera. The analytical sensitivity was 1:8, and no cross-reactivity was observed with the tested sera positive for antibodies against eight other swine pathogens. Intra- and inter-batch coefficients of variation were below 10%. In an independent panel of 305 field sera, the positive, negative, and overall percent agreements with a commercial APP ApxIV bELISA kit were 90.4%, 100%, and 96.1%, respectively, with a Cohen's kappa of 0.917 (95% CI: 0.872-0.963). Further validation using samples with independently confirmed infection status is required to establish its diagnostic accuracy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers